Air Conditioning System (For Automatic Air Conditioning System) Problem Symptoms Table

Vehicle Interior. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
Heating Air Conditioning. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25

Air Conditioning System (For Automatic Air Conditioning System) -- Problem Symptoms Table


HINT:
  1. Use the table below to help determine the cause of problem symptoms. If multiple suspected areas are listed, the potential causes of the symptoms are listed in order of probability in the "Suspected Area" column of the table. Check each symptom by checking the suspected areas in the order they are listed. Replace parts as necessary.
  2. Inspect the fuses and relays related to this system before inspecting the suspected areas below.

Air Conditioning
Symptom
Suspected Area
See page
All functions of the air conditioning system do not operate
Proceed to "IG Power Source Circuit"
HILUX_TGN26 RM000002LLU04LX.html
Integration panel sub-assembly
HILUX_TGN26 RM000001K3A023X.html
No. 1 cooler wire
HILUX_TGN26 RM000004QZA00AX.html
Air conditioning amplifier assembly
HILUX_TGN26 RM000001K3A024X.html
Air Flow Control: No blower operation
Indicator check
HILUX_TGN26 RM000002LIT02JX.html
Integration panel sub-assembly
HILUX_TGN26 RM000001K3A023X.html
No. 1 cooler wire
HILUX_TGN26 RM000004QZA00AX.html
Proceed to "Heater Relay Circuit"
HILUX_TGN26 RM000001DTG01VX.html
Proceed to "Blower Motor Circuit"
HILUX_TGN26 RM000001DTI02BX.html
Air Flow Control: No blower control
Indicator check
HILUX_TGN26 RM000002LIT02JX.html
Integration panel sub-assembly
HILUX_TGN26 RM000001K3A023X.html
No. 1 cooler wire
HILUX_TGN26 RM000004QZA00AX.html
Proceed to "Blower Motor Circuit"
HILUX_TGN26 RM000001DTI02BX.html
Air Flow Control: Insufficient air flow
Proceed to "Blower Motor Circuit"
HILUX_TGN26 RM000001DTI02BX.html
Temperature Control: No cool air comes out
Integration panel sub-assembly
HILUX_TGN26 RM000001K3A023X.html
No. 1 cooler wire
HILUX_TGN26 RM000004QZA00AX.html
Check volume of refrigerant
HILUX_TGN26 RM000001R8Z02GX.html
Check for refrigerant gas leak
HILUX_TGN26 RM000001R8Y02IX.html
Cooler expansion valve
HILUX_TGN26 RM0000012JQ02TX.html
Proceed to "Pressure Switch Circuit"
HILUX_TGN26 RM000001DTB01VX.html
Proceed to "Air Conditioning Compressor Magnetic Clutch Circuit"
HILUX_TGN26 RM000001DTH020X.html
Proceed to "Front Air Mix Damper Control Servo Motor Circuit"
HILUX_TGN26 RM000001LZM014X.html
Proceed to "Ambient Temperature Sensor Circuit"
HILUX_TGN26 RM000001DT901XX.html
Proceed to "Evaporator Temperature Sensor Circuit"
HILUX_TGN26 RM000001DTA01XX.html
Proceed to "Room Temperature Sensor Circuit"
HILUX_TGN26 RM000001DT801WX.html
Proceed to "Solar Sensor Circuit"
HILUX_TGN26 RM000001DTK01YX.html
Proceed to "Vehicle Speed Signal Circuit"
HILUX_TGN26 RM000001DTJ01WX.html
Cooler compressor assembly (for 1KD-FTV)
HILUX_TGN26 RM0000012JZ038X.html
Cooler compressor assembly (for 2TR-FBE)
HILUX_TGN26 RM0000012JZ036X.html
Cooler compressor assembly (for 1GR-FE)
HILUX_TGN26 RM0000012JZ02PX.html
Air conditioning amplifier assembly
HILUX_TGN26 RM000001K3A024X.html
Temperature Control: No warm air comes out
Integration panel sub-assembly
HILUX_TGN26 RM000001K3A023X.html
No. 1 cooler wire
HILUX_TGN26 RM000004QZA00AX.html
Proceed to "Front Air Mix Damper Control Servo Motor Circuit"
HILUX_TGN26 RM000001LZM014X.html
Proceed to "Ambient Temperature Sensor Circuit"
HILUX_TGN26 RM000001DT901XX.html
Proceed to "Evaporator Temperature Sensor Circuit"
HILUX_TGN26 RM000001DTA01XX.html
Proceed to "Room Temperature Sensor Circuit"
HILUX_TGN26 RM000001DT801WX.html
Proceed to "Solar Sensor Circuit"
HILUX_TGN26 RM000001DTK01YX.html
Proceed to "Engine Coolant Temperature Communication Circuit"
HILUX_TGN26 RM000001LZL017X.html
Proceed to "Vehicle Speed Signal Circuit"
HILUX_TGN26 RM000001DTJ01WX.html
Air conditioning amplifier assembly
HILUX_TGN26 RM000001K3A024X.html
Temperature Control: Output air is warmer or cooler than set temperature or response is slow
Integration panel sub-assembly
HILUX_TGN26 RM000001K3A023X.html
No. 1 cooler wire
HILUX_TGN26 RM000004QZA00AX.html
Check volume of refrigerant
HILUX_TGN26 RM000001R8Z02GX.html
Check for refrigerant gas leak
HILUX_TGN26 RM000001R8Y02IX.html
Proceed to "Front Air Mix Damper Control Servo Motor Circuit"
HILUX_TGN26 RM000001LZM014X.html
Proceed to "Ambient Temperature Sensor Circuit"
HILUX_TGN26 RM000001DT901XX.html
Proceed to "Evaporator Temperature Sensor Circuit"
HILUX_TGN26 RM000001DTA01XX.html
Proceed to "Room Temperature Sensor Circuit"
HILUX_TGN26 RM000001DT801WX.html
Proceed to "Solar Sensor Circuit"
HILUX_TGN26 RM000001DTK01YX.html
Proceed to "Engine Coolant Temperature Communication Circuit"
HILUX_TGN26 RM000001LZL017X.html
Proceed to "Vehicle Speed Signal Circuit"
HILUX_TGN26 RM000001DTJ01WX.html
Air conditioning amplifier assembly
HILUX_TGN26 RM000001K3A024X.html
Temperature Control: No temperature control (only MAX COOL or MAX WARM)
Integration panel sub-assembly
HILUX_TGN26 RM000001K3A023X.html
No. 1 cooler wire
HILUX_TGN26 RM000004QZA00AX.html
Proceed to "Front Air Mix Damper Control Servo Motor Circuit"
HILUX_TGN26 RM000001LZM014X.html
Proceed to "Ambient Temperature Sensor Circuit"
HILUX_TGN26 RM000001DT901XX.html
Proceed to "Evaporator Temperature Sensor Circuit"
HILUX_TGN26 RM000001DTA01XX.html
Proceed to "Room Temperature Sensor Circuit"
HILUX_TGN26 RM000001DT801WX.html
Proceed to "Solar Sensor Circuit"
HILUX_TGN26 RM000001DTK01YX.html
Proceed to "Vehicle Speed Signal Circuit"
HILUX_TGN26 RM000001DTJ01WX.html
Air conditioning amplifier assembly
HILUX_TGN26 RM000001K3A024X.html
No air inlet control
Proceed to "Air Inlet Damper Control Servo Motor Circuit"
HILUX_TGN26 RM000001DTC01VX.html
Air conditioning amplifier assembly
HILUX_TGN26 RM000001K3A024X.html
No air flow mode control
Proceed to "Air Outlet Damper Control Servo Motor Circuit"
HILUX_TGN26 RM000001DTD01VX.html
Air conditioning amplifier assembly
HILUX_TGN26 RM000001K3A024X.html
Engine idle up does not occur or is continuous
Proceed to "Air Conditioning Compressor Magnetic Clutch Circuit"
HILUX_TGN26 RM000001DTH020X.html
Air conditioning amplifier assembly
HILUX_TGN26 RM000001K3A024X.html
Proceed to "ECD System (for 1KD-FTV [w/ EGR Cooler])"
HILUX_TGN26 RM0000012WB06VX.html
Proceed to "ECD System (for 1KD-FTV [w/o EGR Cooler])"
HILUX_TGN26 RM0000012WB06WX.html
Proceed to "ECD System (for 1KD-FTV [for DPF])"
HILUX_TGN26 RM0000012WB06UX.html
Proceed to "ECD System (for 1KD-FTV [for i-ART])"
HILUX_TGN26 RM0000012WB06XX.html
Proceed to "SFI System (for 2TR-FBE)"
HILUX_TGN26 RM000000PD90WSX.html
Proceed to "SFI System (for 1GR-FE)"
HILUX_TGN26 RM000000PD90WQX.html
Diagnostic trouble codes are not stored, and set mode is cleared when ignition switch is off
Proceed to "Back-up Power Source Circuit"
HILUX_TGN26 RM000002LLV04QX.html
Air conditioning amplifier assembly
HILUX_TGN26 RM000001K3A024X.html