Engine Hybrid System. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
1Gr-Fe Engine Control. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
Sfi System -- How To Proceed With Troubleshooting |
- HINT:
- *: Use the intelligent tester.
1.VEHICLE BROUGHT TO WORKSHOP |
|
2.CUSTOMER PROBLEM ANALYSIS |
|
3.CONNECT INTELLIGENT TESTER TO DLC3 |
- HINT:
- If the display indicates a communication fault in the tester, inspect the DLC3.
|
4.CHECK DTC AND FREEZE FRAME DATA* |
Check DTC (HILUX_TGN26 RM000000PDK12JX.html).
Check freeze frame data (HILUX_TGN26 RM000000PDS0WKX.html).
- HINT:
- Record or print DTCs and freeze frame data, if necessary.
|
5.CLEAR DTC AND FREEZE FRAME DATA* |
Clear DTC and freeze frame data (HILUX_TGN26 RM000000PDK12JX.html).
|
6.CONDUCT VISUAL INSPECTION |
|
7.SET CHECK MODE DIAGNOSIS* |
Switch the ECM from the normal mode to check mode.
- HINT:
- Refer to Check Mode Procedure (HILUX_TGN26 RM000000PDL0O4X.html).
|
8.CONFIRM PROBLEM SYMPTOMS |
Confirm problem symptoms.
- HINT:
- Refer to Problem Symptoms Table (HILUX_TGN26 RM000000PDG0R6X.html).
- If the engine does not start, first perform the "Check DTC" procedures and "Conduct Basic Inspection" procedures below.
Result | Proceed to |
Malfunction does not occur | A |
Malfunction occurs | B |
|
| ||||
|
9.SIMULATE SYMPTOMS |
- HINT:
- Refer to Symptom Simulation (HILUX_TGN26 RM000004QR7008X.html).
|
10.CHECK DTC* |
Check for DTCs.
- HINT:
- Refer to DTC Check / Clear (HILUX_TGN26 RM000000PDK12JX.html).
Result | Proceed to |
Trouble code output | A |
No code output | B |
|
| ||||
|
11.REFER TO DTC CHART |
- HINT:
- Refer to Diagnostic Trouble Code Chart (HILUX_TGN26 RM000002ZSO00TX.html).
|
12.CONDUCT BASIC INSPECTION |
Conduct basic inspection (HILUX_TGN26 RM000000PDM0M4X.html).
Result | Proceed to |
Malfunctioning parts not confirmed | A |
Malfunctioning parts confirmed | B |
|
| ||||
|
13.REFER TO PROBLEM SYMPTOMS TABLE |
- HINT:
- Refer to Problem Symptoms Table (HILUX_TGN26 RM000000PDG0R6X.html).
Result | Proceed to |
Malfunctioning circuit confirmed | A |
Malfunctioning parts confirmed | B |
|
| ||||
|
14.CHECK ECM POWER SOURCE CIRCUIT |
Check the ECM power source circuit.
- HINT:
- Refer to ECM Power Source Circuit (HILUX_TGN26 RM000000WZ0077X.html).
|
15.CONDUCT CIRCUIT INSPECTION |
Result | Proceed to |
Malfunction not confirmed | A |
Malfunction confirmed | B |
|
| ||||
|
16.CHECK FOR INTERMITTENT PROBLEMS |
Check for intermittent problems.
- HINT:
- Refer to Check for Intermittent Problems (HILUX_TGN26 RM000000PDQ0YKX.html).
|
17.CONDUCT PARTS INSPECTION |
|
18.IDENTIFY PROBLEM |
|
19.ADJUST AND/OR REPAIR |
|
20.CONDUCT CONFIRMATION TEST |
| |||||
|
---|