Dtc 42 Air Inlet Damper Control Servo Motor Circuit
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
PERFORM ACTUATOR CHECK
CHECK HARNESS AND CONNECTOR (RECIRCULATION DAMPER SERVO - AIR CONDITIONING AMPLIFIER)
REPLACE RECIRCULATION DAMPER SERVO SUB-ASSEMBLY
DTC 42 Air Inlet Damper Control Servo Motor Circuit |
DESCRIPTION
The recirculation damper servo sub-assembly sends pulse signals to inform the air conditioning amplifier assembly of the damper position. The air conditioning amplifier assembly activates the motor (normal or reverse) based on the signals to move the air inlet control damper to any position, which controls the intake air settings.- HINT:
- This DTC is also output if the air inlet control damper and damper link are malfunctioning or unable to move properly. When this DTC is output, confirm that the mechanical parts of the damper and damper link are not defective or damaged.
DTC Code
| Detection Item
| Trouble Area
|
42
| The air inlet control damper position does not change when the air conditioning amplifier assembly operates the recirculation damper servo sub-assembly.
| - Recirculation damper servo sub-assembly
- Harness or connector
- Air conditioning amplifier assembly
|
WIRING DIAGRAM
INSPECTION PROCEDURE
Remove the glove box to visually check the recirculation damper servo sub-assembly operation (HILUX_TGN26 RM000003R7I00IX.html).
Enter actuator check mode (HILUX_TGN26 RM000003O1100QX.html).
Check that the air inlet control damper position changes according to the display code.
Display Code
| Air Inlet Control Damper Position
|
0
| Fresh
|
1
| Fresh
|
2
| Recirculation/fresh (50%)
|
3
| Recirculation
|
4
| Recirculation
|
5
| Fresh
|
6
| Fresh
|
7
| Recirculation
|
8
| Fresh
|
9
| Fresh
|
- OK:
- Air inlet control damper position changes in accordance with each display code.
- HINT:
- The progression through the steps of the actuator check can be changed from automatic to manual by pressing the front DEF switch.
ResultResult
| Proceed to
|
OK (When troubleshooting according to problem symptoms table.)
| A
|
OK (When troubleshooting according to DTC.)
| B
|
NG
| C
|
2.CHECK HARNESS AND CONNECTOR (RECIRCULATION DAMPER SERVO - AIR CONDITIONING AMPLIFIER) |
Disconnect the G143 recirculation damper servo sub-assembly connector.
Disconnect the G94 and G95 air conditioning amplifier assembly connectors.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
G143-5 (REC) - G94-22 (AIR)
| Always
| Below 1 Ω
|
G143-4 (FRS) - G94-23 (AIF)
|
G143-2 (B) - G95-17 (PIA)
|
G143-3 (L) - G95-16 (AGND)
|
G143-1 (SG) - G95-21 (AUXO)
|
G143-5 (REC) - Body ground
| Always
| 10 kΩ or higher
|
G143-4 (FRS) - Body ground
|
G143-2 (B) - Body ground
|
G143-3 (L) - Body ground
|
G143-1 (SG) - Body ground
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
3.REPLACE RECIRCULATION DAMPER SERVO SUB-ASSEMBLY |
Temporally replace the recirculation damper servo sub-assembly with a new or normally functioning one (HILUX_TGN26 RM0000012JQ02TX.html).
Check the air inlet control damper operates normally.
- OK:
- Air inlet control damper operates normally.
OK |
|
|
|
END (RECIRCULATION DAMPER SERVO IS DEFECTIVE) |
|