Air Conditioning Amplifier (For Automatic Air Conditioning System) Inspection

Vehicle Interior. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
Heating Air Conditioning. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25

  1. INSPECT NO. 1 COOLER WIRE

Air Conditioning Amplifier (For Automatic Air Conditioning System) -- Inspection



1. INSPECT NO. 1 COOLER WIRE


  1. Measure the resistance according to the value(s) in the table below.


    Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.Heating Air Conditioning.Air Conditioning System (For Automatic Air Conditioning System).Air Conditioning Amplifier (For Automatic Air Conditioning System)  Inspection

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    A1 - B1
    Always
    Below 1 Ω
    A2 - B2
    Always
    Below 1 Ω
    A3 - B3
    Always
    Below 1 Ω
    A4 - B4
    Always
    Below 1 Ω
    A5 - B5
    Always
    Below 1 Ω
    A6 - B6
    Always
    Below 1 Ω
    A7 - B7
    Always
    Below 1 Ω
    A8 - B8
    Always
    Below 1 Ω
    A9 - B9
    Always
    Below 1 Ω
    A10 - B10
    Always
    Below 1 Ω
    A11 - B11
    Always
    Below 1 Ω
    A12 - B12
    Always
    Below 1 Ω
    A13 - B13
    Always
    Below 1 Ω
    A14 - B14
    Always
    Below 1 Ω
    A15 - B15
    Always
    Below 1 Ω
    If the result is not as specified, replace the No. 1 cooler wire.

    Text in Illustration
    *a
    Terminal A
    *b
    Terminal B