Engine Hybrid System. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
1Kd-Ftv Engine Control. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
Manifold Absolute Pressure Sensor (W/ Glow Plug Controller) -- On-Vehicle Inspection |
1. INSPECT MANIFOLD ABSOLUTE PRESSURE SENSOR |
Inspect the power source voltage.
Disconnect the manifold absolute pressure sensor connector.
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection Switch Condition Specified Condition 3 (VC) - 1 (E) Ignition switch ON 4.75 to 5.25 V
If the result is not as specified, inspect the wire harness or ECM (for i-ART: HILUX_TGN26 RM0000013FU050X.html, for DPF: HILUX_TGN26 RM0000013FU04YX.html).Text in Illustration *a Front view of wire harness connector
(to Manifold Absolute Pressure Sensor)Connect the manifold absolute pressure sensor connector.
Check the power supply.
Turn the ignition switch to ON.
Disconnect the vacuum hose from the manifold absolute pressure sensor.
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection Condition Specified Condition C167-12 (PIM) - C167-6 (EPIM)*A
C114-5 (PIM) - C114-14 (E2)*B-13.3 kPa (100 mmHg, 3.94 in.Hg) 0.0 to 0.3 V -26.6 kPa (199 mmHg, 7.85 in.Hg) 0.1 to 0.4 V -40 kPa (300 mmHg, 11.81 in.Hg) 0.3 to 0.6 V
Text in Illustration *A for i-ART *B for DPF *a Component without harness connected
(ECM)Vacuum - HINT:
- The values in the "Condition" column are gauge pressures.
Using SST, measure the voltage according to the value(s) in the table below.
- SST
- 09992-00242
- Standard Voltage:
Tester Connection Condition Specified Condition C167-12 (PIM) - C167-6 (EPIM)*A
C114-5 (PIM) - C114-14 (E2)*B19.6 kPa (0.20 kgf/cm2, 2.84 psi) 0.1 to 0.4 V 39.2 kPa (0.40 kgf/cm2, 5.69 psi) 0.3 to 0.6 V 58.8 kPa (0.60 kgf/cm2, 8.53 psi) 0.5 to 0.8 V 78.5 kPa (0.80 kgf/cm2, 11.4 psi) 0.7 to 1.1 V 98.0 kPa (1.00 kgf/cm2, 14.2 psi) 0.9 to 1.3 V
Text in Illustration *A for i-ART *B for DPF *a Component without harness connected
(ECM)Pressure - HINT:
- The values in the "Condition" column are gauge pressures.