Dtc B1695/16 Door Side Airbag Sensor Lh Malfunction
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
CHECK CONNECTORS
CHECK WIRE HARNESS (OPEN)
CHECK WIRE HARNESS (SHORT TO B+)
CHECK WIRE HARNESS (SHORT TO GROUND)
CHECK DOOR SIDE AIRBAG SENSOR LH
CHECK REAR AIRBAG SENSOR LH
CHECK FRONT DOOR WIRE LH (OPEN)
CHECK FRONT DOOR WIRE LH (SHORT TO B+)
CHECK FRONT DOOR WIRE LH (SHORT TO GROUND)
DTC B1695/16 Door Side Airbag Sensor LH Malfunction |
DESCRIPTION
The door side airbag sensor LH circuit consists of the center airbag sensor assembly, side airbag sensor LH, door side airbag sensor LH and rear airbag sensor LH.The side airbag sensor LH, door side airbag sensor LH and rear airbag sensor LH detect impacts to the vehicle and send signals to the center airbag sensor assembly to determine if the airbags should be deployed.DTC B1695/16 is recorded when a malfunction is detected in the door side airbag sensor LH circuit.DTC No.
| DTC Detection Condition
| Trouble Area
|
B1695/16
| - The center airbag sensor assembly receives an open circuit signal, a short circuit to ground or a short circuit to B+ signal in the door side airbag sensor LH circuit for 2 seconds.
- Door side airbag sensor LH malfunction
- Rear airbag sensor LH malfunction
- Center airbag sensor assembly malfunction
| - Floor wire
- Front door wire LH
- Door side airbag sensor LH
- Rear airbag sensor LH
- Center airbag sensor assembly
|
WIRING DIAGRAM
INSPECTION PROCEDURE
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Check that the connectors are properly connected to the door side airbag sensor LH and rear airbag sensor LH. Also check that the connectors that link the floor wire and front door wire LH are properly connected.
- OK:
- The connectors are properly connected.
- HINT:
- If the connectors are not connected securely, reconnect the connectors and proceed to the next inspection.
Disconnect the connectors from the door side airbag sensor LH and rear airbag sensor LH. Also disconnect the connectors that link the floor wire and front door wire LH.
Check that the terminals of the connectors are not damaged.
- OK:
- The terminals are not deformed or damaged.
2.CHECK WIRE HARNESS (OPEN) |
Connect the connectors that link the floor wire and front door wire LH.
Using SST, connect terminals 2 (BDL+) and 1 (BDL-) of connector E.
- NOTICE:
- Do not forcibly insert SST into the terminals of the connector when connecting.
- SST
- 09843-18040
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
L59-1 (BDL+) - L59-2 (BDL-)
| Always
| Below 1 Ω
|
3.CHECK WIRE HARNESS (SHORT TO B+) |
Disconnect SST from connector E.
Connect the cable to the negative (-) battery terminal.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
| Switch Condition
| Specified Condition
|
L59-1 (BDL+) - Body ground
| Ignition switch ON
| Below 1 V
|
L59-2 (BDL-) - Body ground
| Ignition switch ON
| Below 1 V
|
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
4.CHECK WIRE HARNESS (SHORT TO GROUND) |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
L59-1 (BDL+) - Body ground
| Always
| 1 MΩ or higher
|
L59-2 (BDL-) - Body ground
| Always
| 1 MΩ or higher
|
5.CHECK DOOR SIDE AIRBAG SENSOR LH |
Connect the connector to the rear airbag sensor LH.
Interchange the door side airbag sensor LH with RH and connect the connectors.
Connect the cable to the negative (-) battery terminal.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Clear the DTCs stored in the memory (COROLLA_ZRE142 RM000000XFE0H1X.html).
Turn the ignition switch off.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Check for DTCs (COROLLA_ZRE142 RM000000XFE0H1X.html).
- Result:
Result
| Proceed to
|
DTC B1695/16 is output.
| A
|
DTC B1690/15 is output.
| B
|
DTCs B1690/15 and B1695/16 are not output.
| C
|
- HINT:
- Codes other than DTCs B1690/15 and B1695/16 may be output at this time, but they are not related to this check.
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Return the door side airbag sensors LH and RH to their original positions and connect the connectors.
6.CHECK REAR AIRBAG SENSOR LH |
Interchange the rear airbag sensor LH with RH and connect the connectors.
Connect the cable to the negative (-) battery terminal.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Clear the DTCs stored in the memory (COROLLA_ZRE142 RM000000XFE0H1X.html).
Turn the ignition switch off.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Check for DTCs (COROLLA_ZRE142 RM000000XFE0H1X.html).
- Result:
Result
| Proceed to
|
DTCs B1690/15 and B1695/16 are not output.
| A
|
DTC B1690/15 is output.
| B
|
DTC B1695/16 is output.
| C
|
- HINT:
- Codes other than DTCs B1690/15 and B1695/16 may be output at this time, but they are not related to this check.
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Return the rear airbag sensors LH and RH to their original positions and connect the connectors.
7.CHECK FRONT DOOR WIRE LH (OPEN) |
Disconnect the front door wire LH connector from the floor wire.
- HINT:
- SST has already been inserted into connector E.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
IL1-1 (BDL+) - IL1-2 (BDL-)
| Always
| Below 1 Ω
|
Disconnect SST from connector E.
| REPLACE FRONT DOOR WIRE LH |
|
|
8.CHECK FRONT DOOR WIRE LH (SHORT TO B+) |
Disconnect the front door wire LH connector from the floor wire.
Connect the cable to the negative (-) battery terminal.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
| Switch Condition
| Specified Condition
|
IL1-1 (BDL+) - Body ground
| Ignition switch ON
| Below 1 V
|
IL1-2 (BDL-) - Body ground
| Ignition switch ON
| Below 1 V
|
| REPLACE FRONT DOOR WIRE LH |
|
|
9.CHECK FRONT DOOR WIRE LH (SHORT TO GROUND) |
Disconnect the front door wire LH connector from the floor wire.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
IL1-1 (BDL+) - Body ground
| Always
| 1 MΩ or higher
|
IL1-2 (BDL-) - Body ground
| Always
| 1 MΩ or higher
|
| REPLACE FRONT DOOR WIRE LH |
|
|