Body Electrical. Camry. Acv40 Gsv40
Lighting. Camry. Acv40 Gsv40
Hazard Warning Switch -- Inspection |
1. INSPECT HAZARD WARNING SIGNAL SWITCH ASSEMBLY |
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection Condition Specified Condition 5 - 4 OFF 10 kΩ or higher 5 - 4 ON Below 1 Ω
![]() |
Apply battery voltage to the hazard warning signal switch assembly connector.
- OK:
Measurement Condition Specified Condition Battery positive (+) → Terminal 7
Battery negative (-) → Terminal 8Illumination comes on