Purge Valve -- Inspection |
1. INSPECT PURGE VSV |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition 1 - 2 20°C (68°F) 23 to 26 Ω 1 - Body ground Always 10 MΩ or higher 2 - Body ground
- HINT:
- When measuring the coil resistance make sure that the surface temperature of the purge VSV is 20°C.
Check the operation.
Check that air does not flow from port E to port F.
Text in Illustration *1 Port E *2 Port F Air Apply battery voltage across the terminals.
Check that air flows from port E to port F.
If the result is not as specified, replace the purge VSV.Text in Illustration *1 Port E *2 Port F Air