Vacuum Switching Valve -- Inspection |
1. INSPECT VACUUM SWITCHING VALVE (for EGR Cut) |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition 1 - 2 20°C (68°F) 37 to 44 Ω 1 - Body ground
2 - Body ground20°C (68°F) 1 MΩ or higher
Check the operation of the vacuum switching valve.
Attach a vacuum pump to port E and check that air does not flow from the filter to port E.
Text in Illustration *1 Port E *2 Filter Apply battery voltage across terminals 1 and 2.
Text in Illustration *1 Port E *2 Filter Attach a vacuum pump to port E and check that air flows from the filter to port E.
If the result is not as specified, replace the vacuum switching valve.