Двигатель. COROLLA, AURIS. ZZE150 ZRE151,152 NDE150
Система Охлаждения 2Ad-Fhv. COROLLA, AURIS. ZZE150 ZRE151,152 NDE150
Электродвигатель Вентилятора Системы Охлаждения -- Проверка Без Снятия С Автомобиля |
1. INSPECT NO. 1 COOLING FAN MOTOR |
Disconnect the No. 1 cooling fan motor connector.
![]() |
Connect the battery and an ammeter to the No. 1 cooling fan motor connector.
Check that the No. 1 cooling fan motor rotates smoothly, and then check the reading on the ammeter.
- Standard current:
Item Specified Condition Cooling fan motor 11.7 to 14.7 A at 20°C (68°F), 12 V
Reconnect the No. 1 cooling fan motor connector.
2. INSPECT NO. 2 COOLING FAN MOTOR (w/ Air Conditioning System) |
Disconnect the No. 2 cooling fan motor connector.
![]() |
Connect the battery and an ammeter to the No. 2 cooling fan motor connector.
Check that the No. 2 cooling fan motor rotates smoothly, and then check the reading on the ammeter.
- Standard current:
Item Specified Condition Cooling fan motor 7.9 to 10.9 A at 20°C (68°F), 12 V
Reconnect the No. 2 cooling fan motor connector.