Land Cruiser URJ200 URJ202 GRJ200 VDJ200 - HEATING / AIR CONDITIONING
REFRIGERANT - REPLACEMENT
1. RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM |
Start the engine.
Turn the A/C switch on.
Operate the cooler compressor while the engine speed is approximately 1000 rpm for 5 to 6 minutes to circulate the refrigerant and collect the compressor oil remaining in each component into the cooler compressor.
Stop the engine.
Recover the refrigerant from the A/C system using a refrigerant recovery unit.
2. CHARGE REFRIGERANT |
- SST
- 09985-20010(09985-02130,09985-02150,09985-02090,09985-02110,09985-02010,09985-02050,09985-02060,09985-02070)
Perform vacuum purging using a vacuum pump.
Charge refrigerant HFC-134a (R134a).
Condenser Core Thickness | Air Conditioning Type | Cool Box | Refrigerant Charging Amount |
22 mm (0.866 in.) | w/o Rear Cooler | w/ Cool Box | 870 +/-30 g (30.7 +/-1.1 oz.) |
w/o Cool Box | 870 +/-30 g (30.7 +/-1.1 oz.) | ||
w/ Rear Cooler | w/ Cool Box | 1010 +/-30 g (35.6 +/-1.1 oz.) | |
w/o Cool Box | 960 +/-30 g (33.9 +/-1.1 oz.) | ||
16 mm (0.630 in.) | w/o Rear Cooler | w/ Cool Box | 770 +/-30 g (27.2 +/-1.1 oz.) |
w/o Cool Box | 770 +/-30 g (27.2 +/-1.1 oz.) | ||
w/ Rear Cooler | w/ Cool Box | 970 +/-30 g (34.2 +/-1.1 oz.) | |
w/o Cool Box | 920 +/-30 g (32.5 +/-1.1 oz.) |
- NOTICE:
3. WARM UP ENGINE |
Warm up the engine at less than 1850 rpm for 2 minutes or more after charging the refrigerant.
- NOTICE:
- Be sure to warm up the compressor when turning the A/C switch is on after removing and installing the cooler refrigerant lines (including the compressor), to prevent damage to the compressor.
4. CHECK FOR REFRIGERANT GAS LEAK |
After recharging the refrigerant gas, check for refrigerant gas leakage using a halogen leak detector.
Perform the operation under these conditions:

Using a halogen leak detector, check the refrigerant line for leakage.
If a gas leak is not detected on the drain hose, remove the blower motor control (blower resistor) from the cooling unit. Insert the halogen leak detector sensor into the unit and perform the test.
Disconnect the connector and wait for approximately 20 minutes. Bring the halogen leak detector close to the pressure switch and perform the test.