Can Communication System (For Lhd) - Ecm Communication Stop Mode
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
CHECK HARNESS AND CONNECTOR (ECM - BATTERY AND BODY GROUND)
CAN COMMUNICATION SYSTEM (for LHD) - ECM Communication Stop Mode
DESCRIPTION
Detection Item | Symptom | Trouble Area |
ECM Communication Stop Mode | Either condition is met:
"ECM (Engine)" is not displayed on the "Bus Check" screen.
"ECM Communication Stop Mode" in "DTC Communication Table" applies.
| Power source or inside of ECM
ECM
|
WIRING DIAGRAM


INSPECTION PROCEDURE
- Inspect the fuses for circuits related to this system before performing the following inspection procedure.
1.CHECK HARNESS AND CONNECTOR (ECM - BATTERY AND BODY GROUND) |
Disconnect the A38 and C45 ECM connectors.

Text in Illustration*A | except 1VD-FTV | *B | for 1VD-FTV |
*a | Front view of wire harness connector (to ECM) | - | - |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
except 1VD-FTVTester Connection | Condition | Specified Condition |
C45-81 (E1) - Body ground | Always | Below 1 Ω |
C45-42 (E02) - Body ground | Always | Below 1 Ω |
C45-43 (E01) - Body ground | Always | Below 1 Ω |
C45-82 (ME01) - Body ground | Always | Below 1 Ω |
for 1VD-FTVTester Connection | Condition | Specified Condition |
C45-81 (E1) - Body ground | Always | Below 1 Ω |
C45-21 (E02) - Body ground | Always | Below 1 Ω |
C45-22 (E01) - Body ground | Always | Below 1 Ω |
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
except 1VD-FTVTester Connection | Condition | Specified Condition |
A38-1 (BATT) - Body ground | Always | 11 to 14 V |
A38-2 (+B2) - Body ground | Battery positive (+) voltage applied to terminal A38-34 (MREL) | 11 to 14 V |
A38-3 (+B) - Body ground | Battery positive (+) voltage applied to terminal A38-34 (MREL) | 11 to 14 V |
for 1VD-FTVTester Connection | Condition | Specified Condition |
A38-20 (BATT) - Body ground | Always | 11 to 14 V |
A38-2 (+B) - Body ground | Battery positive (+) voltage applied to terminal A38-44 (MREL) | 11 to 14 V |
ResultResult | Proceed to |
OK (for 1GR-FE) | A |
OK (for 1UZ-FE) | B |
OK (for 3UR-FE) | C |
OK (for 1VD-FTV) | D |
NG | E |
| |
|
| |
|
| |
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|