Dtc P2716 Pressure Control Solenoid D Electrical (Shift Solenoid Valve Slt)
DESCRIPTION
MONITOR DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
INSPECT NO. 1 TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT)
CHECK HARNESS AND CONNECTOR (NO. 1 TRANSMISSION WIRE - ECM)
INSPECT SHIFT SOLENOID VALVE SLT
DTC P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)
DESCRIPTION
Refer to DTC P0894 ().
DTC Code | DTC Detection Condition | Trouble Area |
P2716 | Conditions (a) or (b) below are detected for 1 sec. or more (1 trip detection logic). (a) SLT - terminal: 0 V (b) SLT - terminal: 12 V | Open or short in shift solenoid valve SLT circuit
Shift solenoid valve SLT
ECM
|
MONITOR DESCRIPTION
When an open or short in the shift solenoid valve SLT circuit is detected, the ECM interprets this as a fault. The ECM will turn on the MIL and store the DTC.
WIRING DIAGRAM

INSPECTION PROCEDURE
1.INSPECT NO. 1 TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT) |
Disconnect the No. 1 transmission wire connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection | Condition | Specified Condition |
13 (SLT+) - 5 (SLT-) | 20°C (68°F) | 5.0 to 5.6 Ω |
13 (SLT+) - Body ground | Always | 10 kΩ or higher |
5 (SLT-) - Body ground | Always | 10 kΩ or higher |
Text in Illustration*a | Component without harness connected (No. 1 Transmission Wire) |
2.CHECK HARNESS AND CONNECTOR (NO. 1 TRANSMISSION WIRE - ECM) |
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
for LHDTester Connection | Condition | Specified Condition |
C45-11 (SLT+) - C45-10 (SLT-) | 20°C (68°F) | 5.0 to 5.6 Ω |
C45-11 (SLT+) - Body ground | Always | 10 kΩ or higher |
C45-10 (SLT-) - Body ground | Always | 10 kΩ or higher |
for RHDTester Connection | Condition | Specified Condition |
C46-11 (SLT+) - C46-10 (SLT-) | 20°C (68°F) | 5.0 to 5.6 Ω |
C46-11 (SLT+) - Body ground | Always | 10 kΩ or higher |
C46-10 (SLT-) - Body ground | Always | 10 kΩ or higher |
Text in Illustration*1 | for LHD |
*2 | for RHD |
*a | Front view of wire harness connector (to ECM) |
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
3.INSPECT SHIFT SOLENOID VALVE SLT
|
Remove the shift solenoid valve SLT.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection | Condition | Specified Condition |
1 - 2 | 20°C (68°F) | 5.0 to 5.6 Ω |
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition | Specified Condition |
Battery positive (+) with a 21 W bulb → Terminal 2
Battery negative (-) → Terminal 1
| Valve moves and makes an operating noise |
Text in Illustration*a | Component without harness connected (Shift Solenoid Valve SLT) |
| REPLACE SHIFT SOLENOID VALVE SLT ()
|
|
|
OK | |
| |
REPAIR OR REPLACE NO. 1 TRANSMISSION WIRE ()
|
|