Power Tilt And Power Telescopic Steering Column System Freeze Frame Data

Steering. Lexus Is250, Is220D. Gse20 Ale20
Steering Column. Lexus Is250, Is220D. Gse20 Ale20
  1. FREEZE FRAME DATA

Power Tilt And Power Telescopic Steering Column System -- Freeze Frame Data



FREEZE FRAME DATA
  1. Connect the intelligent tester to the DLC3.

  2. Turn the engine switch on (IG) and check the FREEZE FRAME DATA by following the prompts on the intelligent tester screen.

    TILT & TELESCO:
    Item
    Measurement Item / Range (Display)
    Normal Condition
    Diagnostic Note
    T&T Autoaway
    Auto away and return function / ON or OFF
    ON: Auto away and return function is allowed
    OFF: Auto away and return function is restrained
    -
    Tilt Position
    Current tilt position data / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
    7000 to 9000 H
    (28672 to 36864 edge)
    -
    Telesco Position
    Current telescopic position data / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
    7000 to 9000 H
    (28672 to 36864 edge)
    -
    Tilt Return Position
    Memorized tilt return position data / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
    7000 to 9000 H
    (28672 to 36864 edge)
    -
    Telesco Return Position
    Memorized telescopic return position data / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
    7000 to 9000 H
    (28672 to 36864 edge)
    -
    T&T Mem 1
    Tilt & telescopic memory position 1 / NOT MEM or MEM
    NOT MEM: Position is not memorized
    MEM: Position is memorized
    -
    Tilt Memory Pos 1
    Tilt data of memory position 1 / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
    7000 to 9000 H
    (28672 to 36864 edge)
    -
    Telesco Memory Pos 1
    Telescopic data of memory position 1 / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
    7000 to 9000 H
    (28672 to 36864 edge)
    -
    T&T Mem 2
    Tilt & telescopic memory position 2 / NOT MEM or MEM
    NOT MEM: Position is not memorized
    MEM: Position is memorized
    -
    Tilt Memory Pos 2
    Tilt data of memory position 2 / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
    7000 to 9000 H
    (28672 to 36864 edge)
    -
    Telesco Memory Pos 2
    Telescopic data of memory position 2 / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
    7000 to 9000 H
    (28672 to 36864 edge)
    -
    T&T Mem 3
    Tilt & telescopic memory position 3 / NOT MEM or MEM
    NOT MEM: Position is not memorized
    MEM: Position is memorized
    -
    Tilt Memory Pos 3
    Tilt data of memory position 3 / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
    7000 to 9000 H
    (28672 to 36864 edge)
    -
    Telesco Memory Pos 3
    Telescopic data of memory position 3 / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
    7000 to 9000 H
    (28672 to 36864 edge)
    -
    Tilt Up Limit
    Uppermost tilt position / NOT MEM or MEM
    NOT MEM: Position is not memorized
    MEM: Position is memorized
    -
    Tilt Up Limit Position
    Uppermost tilt position data / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
    7000 to 9000 H
    (28672 to 36864 edge)
    -
    Tilt Down Limit Pos
    Lowermost tilt position / NOT MEM or MEM
    NOT MEM: Position is not memorized
    MEM: Position is memorized
    -
    Tilt Down Limit Position
    Lowermost tilt position data / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
    7000 to 9000 H
    (28672 to 36864 edge)
    -
    Telesco Short Limit Pos
    Shortest telescopic position / NOT MEM or MEM
    NOT MEM: Position is not memorized
    MEM: Position is memorized
    -
    Telesco Short Limit Pos
    Shortest telescopic position data / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
    7000 to 9000 H
    (28672 to 36864 edge)
    -
    Telesco Long Limit
    Longest telescopic position / NOT MEM or MEM
    NOT MEM: Position is not memorized
    MEM: Position is memorized
    -
    Telesco Long Limit Pos
    Longest telescopic position data / min.: 0000 H (0 edge), max.: FFFF H (65535 edge)
    7000 to 9000 H
    (28672 to 36864 edge)
    -
    Up Switch
    Input state of tilt up by manual switch / ON or OFF
    ON: Tilt up is activated by manual switch
    OFF: Tilt up is not activated by manual switch
    -
    Tilt Up SW (MPX)
    Communication state of tilt up input by manual switch / ON or OFF
    ON: Tilt up is activated by manual switch
    OFF: Tilt up is not activated by manual switch
    -
    Down Switch
    Input state of tilt down by manual switch / ON or OFF
    ON: Tilt down is activated by manual switch
    OFF: Tilt down is not activated by manual switch
    -
    Tilt Down SW (MPX)
    Communication state of tilt down input by manual switch / ON or OFF
    ON: Tilt down is activated by manual switch
    OFF: Tilt down is not activated by manual switch
    -
    Telesco Short Switch
    Input state of telescopic short by manual switch / ON or OFF
    ON: Telescopic short is activated by manual switch
    OFF: Telescopic short is not activated by manual switch
    -
    Telesco Short SW (MPX)
    Communication state of telescopic short input by manual switch / ON or OFF
    ON: Telescopic short is activated by manual switch
    OFF: Telescopic short is not activated by manual switch
    -
    Telesco Long Switch
    Input state of telescopic long by manual switch / ON or OFF
    ON: telescopic long is activated by manual switch
    OFF: Telescopic long is not activated by manual switch
    -
    Telesco Long SW (MPX)
    Communication state of telescopic long input by manual switch / ON or OFF
    ON: Telescopic long is activated by manual switch
    OFF: Telescopic long is not activated by manual switch
    -
    T&T Manual SW Data
    Voltage data of manual switch / min.: 0 V, max.: 5 V
    Neutral position: Below 0.2 V
    Tilt up: 1.67 to 2.13 V
    Tilt down: 0.54 to 0.74 V
    Telescopic contract: 1.08 to 1.40 V
    Telescopic extend: 2.22 to 2.77 V
    -
    Power Source Voltage
    Voltage data of power supply / min.: 0 V, max.: 20 V
    Actual power supply voltage
    10 to 14 V
    -
    Freeze Speed Info
    Vehicle speed data / 0 km/h (0 mph), max.: 255 km/h (158 mph)
    Actual vehicle speed
    -
    IG Switch (MPX)
    Communication state of engine switch / ON or OFF
    ON: Communication is normal
    OFF: Communication is interrupted
    -
    IG Switch
    Input state of engine switch / ON or OFF
    ON: Input signal is normal
    OFF: Input signal is interrupted
    -
    Key Switch / MPX
    Communication state of key switch confirmation signal / ON or OFF
    ON: Communication is normal
    OFF: Communication is interrupted
    -
    Key Code Confirm (MPX)
    Communication state of key code confirmation signal / ON or OFF
    ON: Communication is normal
    OFF: Communication is interrupted
    -
    Receive from Body
    Communication state of body ECU signal / OK or Interruption
    OK: Communication is normal Interruption: Communication is interrupted
    -
    Receive from Seat ECU
    Communication state of seat ECU signal / OK or Interruption
    OK: Communication is normal Interruption: Communication is interrupted
    -
    Receive from Combi
    Communication state of combination switch ECU signal / OK or Interruption
    OK: Communication is normal Interruption: Communication is interrupted
    -
    Receive from Meter
    Communication state of combination meter signal / OK or Interruption
    OK: Communication is normal Interruption: Communication is interrupted
    -
    Power ECU Info
    Communication state of power source control ECU signal / OK or interruption
    OK: Communication is normal
    Interruption: Communication is interrupted
    -