Body Electrical. Lexus Gs430, Gs300. Uzs190 Grs190
Meter. Lexus Gs430, Gs300. Uzs190 Grs190
Combination Meter -- Removal |
1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
- CAUTION:
- Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt pretensioner activation.
2. REMOVE STEERING COLUMN COVER UPPER |
For 3GR-FSE (Click here)
For 3UZ-FE (Click here)
3. REMOVE INSTRUMENT CLUSTER FINISH PANEL SUB-ASSEMBLY |
![]() |
Using a screwdriver, detach the 5 clips.
- HINT:
- Tape the screwdriver tip before use.
Remove the cluster finish panel and then disconnect the connector.
4. REMOVE COMBINATION METER ASSEMBLY |
![]() |
Remove the 4 screws.
Disconnect the connector and remove the combination meter.
5. REMOVE COMBINATION METER GLASS |
![]() |
Using a screwdriver, detach the 2 claws and open the cover.
- HINT:
- Tape the screwdriver tip before use.
Disconnect the 3 connectors.
![]() |
Detach the 7 claws and remove the glass.
![]() |