Electronic Power Steering System Data List / Active Test

Steering. Lexus Gs430, Gs300. Uzs190 Grs190
Power Steering. Lexus Gs430, Gs300. Uzs190 Grs190
  1. DATA LIST

Electronic Power Steering System -- Data List / Active Test



DATA LIST
HINT:
By accessing the data list displayed on the intelligent tester, you can perform such functions as reading the values of switches and sensors without removing any parts. Reading the data list is the first step of troubleshooting and is one method to shorten labor time.
  1. Connect the intelligent tester to the DLC3.

  2. Turn the engine switch on (IG).

  3. Operate the intelligent tester according to the steps on the display and select data list.

    Item
    Item Description/Range (Display)
    Inspection Condition
    Reference Value
    Torque Sensor 1 Output
    Torque sensor 1 rotation angle/
    Min.: 0 deg, Max.: 360 deg
    Steering wheel is turned
    Value changes from 0 to 360° every 22.5° of steering angle
    Torque Sensor 2 Output
    Torque sensor 2 rotation angle/
    Min.: 0 deg, Max.: 360 deg
    Steering wheel is turned
    Value changes from 0 to 360° every 22.5° of steering angle
    Meter Vehicle Velocity
    Vehicle speed from meter/
    Min.: 0 km/h (0 mph), Max.: 255 km/h (158 mph)
    1. Vehicle is stopped
    2. Vehicle is driven at a constant speed
    1. 0 km/h (0 mph)
    2. No significant fluctuation
    Engine Revolution
    Engine revolution/Min.: 0 rpm,
    Max.: 8192 rpm
    Engine is running at a constant speed
    No significant fluctuation
    Motor Actual Current
    Amount of current to motor/
    Min.: -128 A, Max.: 127 A
    Power steering is in operation
    Value changes in proportion to steering effort
    Command Value Current
    Demanded amount of current to motor/
    Min.: -128 A, Max.: 127 A
    Power steering is in operation
    Value changes in proportion to steering effort
    Steering Angle Velocity
    Steering angle speed/Min.: -4096
    deg/sec, Max.: 4064 deg/sec
    Steering wheel is turned
    Value changes in proportion to steering speed
    Thermistor Temperature
    ECU substrate temperature/
    Min.: -50 °C, Max.: 205°C
    Engine switch on (IG)
    -
    PIG Power Supply
    Power source voltage to activate motor/
    Min.: 0 V, Max.: 25.5 V
    Power steering is in operation
    10 to 14 V
    IG Power Supply
    ECU power source voltage/
    Min.: 0 V, Max.: 25.5 V
    Engine switch on (IG)
    10 to 14 V
    TRQ1 Zero Point Value
    Zero point value of torque sensor 1/
    Min.: 0 deg, Max.: 360 deg
    Steering wheel is not turned
    (without load)
    Values differ depending on vehicle
    TRQ2 Zero Point Value
    Zero point value of torque sensor 2/
    Min.: 0 deg, Max.: 360 deg
    Steering wheel is not turned
    (without load)
    Values differ depending on vehicle
    Steering Wheel Torque
    Steering torque/Min.: -7.0 N*m,
    Max.: 7.0 N*m
    Steering wheel is turned
    Value changes in proportion to steering effort
    Motor Rotation Angle
    Motor rotation angle/Min.: 0 deg,
    Max.: 360 deg
    Steering wheel is turned
    Value changes from 0 to 360° every 22.5° of steering angle
    Command Val Current 2
    Amount of current demanded by motor 2/
    Min.: -128 A, Max.: 127 A
    -
    -
    PIG2 Voltage
    Motor drive voltage after pressurization
    Power steering is in operation
    27 to 34 V
    Motor Voltage
    Motor power source voltage/Min.:
    0 V, Max.: 64 V
    Power steering is in operation
    27 to 34 V
    Motor Terminal Volt(U)
    Motor terminal voltage (U phase)/
    Min.: 0 V, Max.: 64 V
    Power steering is in operation
    27 to 34 V
    Motor Terminal Volt(V)
    Motor terminal voltage (V phase)/
    Min.: 0 V, Max.: 64 V
    Power steering is in operation
    27 to 34 V
    Motor Terminal Volt(W)
    Motor terminal voltage (W phase)/
    Min.: 0 V, Max.: 64 V
    Power steering is in operation
    27 to 34 V
    Steering Angle Sens Sig
    Steering angle sensor signal status/
    OK or NG
    -
    -
    Motor Overheat Record
    Continuous overheat prevention control record/
    Rec or Unrec
    -
    -
    Motor Lo Power Record
    PIG power source voltage drop record/
    Rec or Unrec
    -
    -
    Eng Rev Inter Record
    Record of engine revolution signal
    interruption/Rec or Unrec
    -
    -
    Str Angle Inter Record
    Record of steering angle sensor
    signal interruption/Rec or Unrec
    -
    -
    Spd Sig Invalid Record
    Record of vehicle speed signal invalid/
    Rec or Unrec
    -
    -
    Control Mode
    Codes indicating DTC detection timing during ECU control are displayed in hexadecimal
    -
    -
    IG ON/OFF Times
    Number of times IG switch is turned on after DTC detection/
    Min.: 0 time, Max.: 255 times
    -
    -
    The Number of DTCs
    Number of detected DTCs when freeze frame data is stored/
    Min.: 0, Max.: 255
    -
    -
    Assist Map Select State
    Selected assist map/01 to 09,11 or 12
    -
    -
    ECU Identification
    ECU identification information/01 to 09, 11or 12
    -
    -
    Test Mode Status
    Selected mode/
    Normal or Test
    -
    -