Lighting System Hazard Warning Switch Circuit
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
READ VALUE USING GTS (HAZARD FLASHER SWITCH)
CHECK VEHICLE TYPE
INSPECT MULTI-DISPLAY ASSEMBLY (HAZARD WARNING SIGNAL SWITCH)
CHECK HARNESS AND CONNECTOR (MULTI-DISPLAY - COMBINATION METER AND BODY GROUND)
INSPECT HAZARD WARNING SIGNAL SWITCH
CHECK HARNESS AND CONNECTOR (HAZARD WARNING SIGNAL SWITCH - COMBINATION METER AND BODY GROUND)
INSPECT CLOCK ASSEMBLY
CHECK HARNESS AND CONNECTOR (CLOCK - COMBINATION METER AND BODY GROUND)
LIGHTING SYSTEM - Hazard Warning Switch Circuit |
DESCRIPTION
The combination meter receives a hazard warning signal switch information signal, and illuminates the turn signal lights.
WIRING DIAGRAM
INSPECTION PROCEDURE
1.READ VALUE USING GTS (HAZARD FLASHER SWITCH) |
Operate the GTS according to the display and select the "Data List".
Combination MeterTester Display
| Measurement Item/Range
| Normal Condition
| Diagnostic Note
|
Hazard Flasher Switch
| Hazard switch signal / ON or OFF
| ON: Hazard switch on OFF: Hazard switch off
| -
|
OK |
|
|
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here) |
|
Check the vehicle type.
ResultResult
| Proceed to
|
w/ Navigation System
| A
|
w/o Audio
| B
|
for radio Receiver Type
| C
|
3.INSPECT MULTI-DISPLAY ASSEMBLY (HAZARD WARNING SIGNAL SWITCH) |
Remove the multi-display (Click here).
Inspect the multi-display (Click here).
4.CHECK HARNESS AND CONNECTOR (MULTI-DISPLAY - COMBINATION METER AND BODY GROUND) |
Disconnect the F79 and F97 multi-display connectors.
Disconnect the E120 combination meter connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
E120-11 (HZSW) - F97-12 (HAZ)
| Always
| Below 1 Ω
|
F79-13 (GND1) - Body ground
|
E120-11 (HZSW) or F97-12 (HAZ) - Body ground
| Always
| 10 kΩ or higher
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
5.INSPECT HAZARD WARNING SIGNAL SWITCH |
Remove the hazard warning signal switch (Click here).
Inspect the hazard warning signal switch (Click here).
| REPLACE HAZARD WARNING SIGNAL SWITCH ASSEMBLY (Click here) |
|
|
6.CHECK HARNESS AND CONNECTOR (HAZARD WARNING SIGNAL SWITCH - COMBINATION METER AND BODY GROUND) |
Disconnect the F130 hazard warning signal connector.
Disconnect the E120 combination meter connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
E120-11 (HZSW) - F130-4 (F)
| Always
| Below 1 Ω
|
F130-1 (E) - Body ground
|
E120-11 (HZSW) or F130-4 (F) - Body ground
| Always
| 10 kΩ or higher
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
Remove the clock (Click here).
Inspect the clock (Click here).
8.CHECK HARNESS AND CONNECTOR (CLOCK - COMBINATION METER AND BODY GROUND) |
Disconnect the g2 clock signal connector.
Disconnect the E120 combination meter connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
E120-11 (HZSW) - g2-5 (F)
| Always
| Below 1 Ω
|
g2-8 (E) - Body ground
|
E120-11 (HZSW) or g2-5 (F) - Body ground
| Always
| 10 kΩ or higher
|