Air Conditioning System (For Automatic Air Conditioning System) Cooling Box Sensor Circuit

Vehicle Interior. Land Cruiser. Urj200, 202 Grj200 Vdj200
Heating Air Conditioning. Land Cruiser. Urj200, 202 Grj200 Vdj200

DESCRIPTION

WIRING DIAGRAM

INSPECTION PROCEDURE

INSPECT FUSE (A/C IG, ECU-B1)

CHECK HARNESS AND CONNECTOR (NO. 1 COOLER WIRING HARNESS - BATTERY)

CHECK HARNESS AND CONNECTOR (NO. 1 COOLER WIRING HARNESS - BODY GROUND)

CHECK NO. 1 COOLER WIRING HARNESS SUB-ASSEMBLY (OPERATION)

CHECK NO. 3 COOLER THERMISTOR

AIR CONDITIONING SYSTEM (for Automatic Air Conditioning System) - Cooling Box Sensor Circuit


DESCRIPTION

The No. 3 cooler thermistor is installed on the evaporator in the cooling box unit to detect the cooled air temperature that has passed through the evaporator and control the cooling box. It sends appropriate signals to the air conditioning amplifier assembly (for cool box). The resistance of the No. 3 cooler thermistor changes in accordance with the cooled air temperature that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly (for cool box) applies voltage (12 V) to the No. 3 cooler thermistor and reads voltage changes as the resistance of the No. 3 cooler thermistor changes.

WIRING DIAGRAM


Land Cruiser. Urj200, 202 Grj200 Vdj200.Heating Air Conditioning.Air Conditioning System (For Automatic Air Conditioning System).Air Conditioning System (For Automatic Air Conditioning System)  Cooling Box Sensor Circuit


INSPECTION PROCEDURE

1.INSPECT FUSE (A/C IG, ECU-B1)
  1. Remove the A/C IG fuse from the cowl side junction block LH.

  1. Remove the ECU-B1 fuse from the engine room relay block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    A/C IG fuse
    Always
    Below 1 Ω
    ECU-B1 fuse
    Always
    Below 1 Ω


NG
REPLACE FUSE
OK


2.CHECK HARNESS AND CONNECTOR (NO. 1 COOLER WIRING HARNESS - BATTERY)


    Land Cruiser. Urj200, 202 Grj200 Vdj200.Heating Air Conditioning.Air Conditioning System (For Automatic Air Conditioning System).Air Conditioning System (For Automatic Air Conditioning System)  Cooling Box Sensor Circuit
  1. Disconnect the No. 1 cooler wiring harness sub-assembly connector.

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    4 (+B) - Body ground
    Always
    11 to 14 V
    1 (B) - Body ground
    Engine switch off
    Below 1 V
    Engine switch on (IG)
    11 to 14 V


NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


3.CHECK HARNESS AND CONNECTOR (NO. 1 COOLER WIRING HARNESS - BODY GROUND)


    Land Cruiser. Urj200, 202 Grj200 Vdj200.Heating Air Conditioning.Air Conditioning System (For Automatic Air Conditioning System).Air Conditioning System (For Automatic Air Conditioning System)  Cooling Box Sensor Circuit
  1. Disconnect the No. 1 cooler wiring harness sub-assembly connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    6 (L) - Body ground
    Always
    Below 1 Ω


NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


4.CHECK NO. 1 COOLER WIRING HARNESS SUB-ASSEMBLY (OPERATION)
  1. Replace the No. 1 cooler wiring harness sub-assembly with a normal one and check that the condition returns to normal.

    OK:
    Same problem does not occur.


NG
Go to step 5
OK

REPLACE NO. 1 COOLER WIRING HARNESS SUB-ASSEMBLY

5.CHECK NO. 3 COOLER THERMISTOR


    Land Cruiser. Urj200, 202 Grj200 Vdj200.Heating Air Conditioning.Air Conditioning System (For Automatic Air Conditioning System).Air Conditioning System (For Automatic Air Conditioning System)  Cooling Box Sensor Circuit
  1. Remove the No. 3 cooler thermistor (Click here).

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 (+) - 2 (-)
    -10°C (14°F)
    7.30 to 9.10 kΩ
    -5°C (23°F)
    5.65 to 6.95 kΩ
    0°C (32°F)
    4.40 to 5.35 kΩ
    5°C (41°F)
    3.40 to 4.15 kΩ
    10°C (50°F)
    2.70 to 3.25 kΩ
    15°C (59°F)
    2.14 to 2.58 kΩ
    20°C (68°F)
    1.71 to 2.05 kΩ
    25°C (77°F)
    1.38 to 1.64 kΩ
    30°C (86°F)
    1.11 to 1.32 kΩ
    NOTICE:
    1. Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
    2. When measuring, the sensor temperature must be the same as the ambient temperature.
    HINT:
    As the temperature increases, the resistance decreases (see the graph).


NG
REPLACE NO. 3 COOLER THERMISTOR (Click here)
OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (for Cool Box) (Click here)