Vehicle Interior. Land Cruiser. Urj200, 202 Grj200 Vdj200
Heating Air Conditioning. Land Cruiser. Urj200, 202 Grj200 Vdj200
Air Conditioning System (For Automatic Air Conditioning System) -- Data List / Active Test |
- HINT:
- Using the intelligent tester to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
- NOTICE:
- In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
DATA LIST |
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Data List.
Enter the following menus: Powertrain / Engine and ECT / Data List.
According to the display on the intelligent tester, read the Data List.
Air Conditioner Tester Display Measurement Item/Range Normal Condition Diagnostic Note Room Temperature Sensor Front room temperature sensor /
Min.: -6.5°C (20.3°F)
Max.: 57.25°C (135.05°F)Actual room temperature for front seat displayed Open in the circuit: -6.5°C (20.3°F).
Short in the circuit: 57.25°C (135.05°F).Ambient Temp Sensor Ambient temperature sensor /
Min.: -23.3°C (-9.94°F)
Max.: 65.95°C (150.71°F)Actual ambient temperature displayed Open in the circuit: -23.3°C (-9.94°F).
Short in the circuit: 65.95°C (150.71°F).Adjusted Ambient Temp Adjusted ambient temperature /
Min.: -30.8°C (-23.44°F)
Max.: 50.8°C (123.44°F)Adjusted ambient temperature displayed - Evaporator Fin Thermistor No. 1 cooler thermistor /
Min.: -29.7°C (-21.46°F)
Max.: 59.55°C (139.19°F)Actual evaporator temperature displayed Open in the circuit: -29.7°C (-21.46°F).
Short in the circuit: 59.55°C (139.19°F).Evaporator Target Temp Target evaporator temperature /
Min.: 1.5°C (34.7°F)
Max.: 4.0°C (39.2°F)Target evaporator temperature displayed - Solar Sensor (D Side) Driver side solar sensor /
Min.: 0, Max.: 255Driver side solar sensor voltage increases as brightness increases Open in the circuit: 0
Short in the circuit: 255Solar Sensor (P Side) Passenger side solar sensor /
Min.: 0, Max.: 255Passenger side solar sensor voltage increases as brightness increases Open in the circuit: 0
Short in the circuit: 255Engine Coolant Temp Engine coolant temperature /
Min.: 1.3°C (34.34°F)
Max.: 90.55°C (194.99°F)Actual engine coolant temperature displayed while engine warmed up - Set Temperature (D Side) Driver side set temperature /
MAX COLD: 15.5°C (59.9°F)
MAX HOT: 32.5°C (90.5°F)Driver side actual set temperature displayed - Set Temperature (P Side) Passenger side set temperature /
MAX COLD: 15.5°C (59.9°F)
MAX HOT: 32.5°C (90.5°F)Passenger side actual set temperature displayed - A/M Servo Targ Pulse (Rear D) Rear air mix damper servo motor target pulse /
Min.: 9, Max.: 54 (for LHD)
Min.: 8, Max.: 53 (for RHD)for LHD - MAX COOL: 9 (pulse)
- MAX HOT: 54 (pulse)
- MAX COOL: 53 (pulse)
- MAX HOT: 8 (pulse)
- A/M Servo Targ Pulse (Rear P) Rear air mix damper servo motor (for front passenger side) target pulse /
Min.: 8, Max.: 53 (for LHD)
Min.: 9, Max.: 54 (for RHD)for LHD - MAX COOL: 53 (pulse)
- MAX HOT: 8 (pulse)
- MAX COOL: 9 (pulse)
- MAX HOT: 54 (pulse)
- Hand Free Telephone Handsfree telephone / OFF or ON ON: Handsfree telephone used
OFF: Handsfree telephone not used- Blower Motor Speed Level Blower motor speed level /
Min.: 0 level,
Max.: 31 levelIncreases in range between 0 and 31 as blower motor speed increases - Regulator Pressure Sensor Refrigerant pressure sensor /
Min.: -0.4566 MPaG
Max.: 3.2943 MPaGActual refrigerant pressure displayed - Room Temp Sensor (Rear) Rear room temperature sensor /
Min.: -6.5°C (20.3°F)
Max.: 57.25°C (135.05°F)Actual rear room temperature displayed Open in the circuit: -6.5°C (20.3°F).
Short in the circuit: 57.25°C (135.05°F).Ambient Temp Sens (Rear) No. 2 cooler thermistor /
Min.: -29.7°C (-21.46°F)
Max.: 59.55°C (139.19°F)Actual rear evaporator temperature displayed Open in the circuit: -29.7°C (-21.46°F).
Short in the circuit: 59.55°C (139.19°F).Blower Motor Level (Rear) Rear blower motor speed level /
Min.: 0, Max.: 31Increases in range between 0 to 31 as rear blower motor speed increases - Air Mix Servo Targ Pulse(D) Air mix damper servo motor (for driver side) target pulse /
Min.: 8, Max.: 90 (for LHD)
Min.: 8, Max.: 90 (for RHD)for LHD - MAX COOL: 90 (pulse)
- MAX HOT: 8 (pulse)
- MAX COOL: 8 (pulse)
- MAX HOT: 90 (pulse)
- Air Mix Servo Targ Pulse(P) Air mix damper servo motor (for front passenger side) target pulse /
Min.: 8, Max.: 90 (for LHD)
Min.: 8, Max.: 90 (for RHD)for LHD - MAX COOL: 8 (pulse)
- MAX HOT: 90 (pulse)
- MAX COOL: 90 (pulse)
- MAX HOT: 8 (pulse)
- Air Inlet Damper Targ Pulse REC/FRS damper servo motor target pulse /
Min.: 9, Max.: 37for LHD
Recirculation: 37 (pulse)
Fresh: 9 (pulse)
for RHD
Recirculation: 9 (pulse)
Fresh: 37 (pulse)- Cool Air Bypass Pulse Cool air bypass damper servo motor target pulse /
Min.: 6, Max.: 57Shut: 6 (pulse)
Open: 57 (pulse)- Electric Heater Count Electric heater count /
Min.: 0, Max.: 3- - Shift Set Temperature Shift set temperature / +2 C, +1 C, NORMAL, -1 C, -2 C Customized value displayed - Air Inlet Mode Air inlet mode / AUTO, MANUAL Customized value displayed - Compressor Mode Compressor mode / AUTO, MANUAL Customized value displayed - Compressor/DEF Mode Compressor/DEF mode / LINK, NORMAL Customized value displayed - Evaporator Control Evaporator control / AUTO, MANUAL Customized value displayed - Button Press Buzzer Button press buzzer / ON or OFF Customized value displayed - Foot/DEF Auto Mode FOOT/DEF auto mode / ON or OFF Customized value displayed - Foot/DEF Auto Blow Up FOOT/DEF auto blower up function / ON or OFF Customized value displayed - Filter Sensor Filter sensor / LESS, NORMAL, MORE Customized value displayed - Rear A/P HI Set Rear A/P HI set / ON or OFF Customized value displayed - Ambient Temperature Shift Ambient temperature shift / +3 C, +2 C, +1 C, NORMAL, -1 C, -2 C, -3 C Customized value displayed - A/O Damper FACE Pos(D) Air outlet damper servo motor (for driver side mode) target pulse /
Min.: 6, Max.: 117FACE1: 117 (pulse)
FACE2: 109 (pulse)
B/L1: 93 (pulse)
B/L2: 81 (pulse)
FOOT-F: 41 (pulse)
FOOT-R: 41 (pulse)
FOOT-D: 52 (pulse)
F/D: 18 (pulse)
DEF: 6 (pulse)- A/O Damper FACE Pos(P) Air outlet damper servo motor (for front passenger side mode) target pulse /
Min.: 6, Max.: 117 (for LHD)
Min.: 9, Max.: 120 (for RHD)for LHD - FACE1: 117 (pulse)
- FACE2: 109 (pulse)
- B/L1: 93 (pulse)
- B/L2: 81 (pulse)
- FOOT-F: 41 (pulse)
- FOOT-R: 41 (pulse)
- FOOT-D: 52 (pulse)
- F/D: 18 (pulse)
- DEF: 6 (pulse)
- FACE1: 9 (pulse)
- FACE2: 17 (pulse)
- B/L1: 33 (pulse)
- B/L2: 45 (pulse)
- FOOT-F: 85 (pulse)
- FOOT-R: 85 (pulse)
- FOOT-D: 74 (pulse)
- F/D: 108 (pulse)
- DEF: 120 (pulse)
- Air Mix Servo Targ Pls(F&R D) Front air mix damper servo motor (for driver side rear air flow) target pulse /
Min.: 13, Max.: 41 (for LHD)
Min.: 5, Max.: 33 (for RHD)for LHD - MAX COOL: 13 (pulse)
- MAX HOT: 41 (pulse)
- MAX COOL: 33 (pulse)
- MAX HOT: 5 (pulse)
- Air Mix Servo Targ Pls(F&R P) Front air mix damper servo motor (for front passenger side rear air flow) target pulse /
Min.: 5, Max.: 33 (for LHD)
Min.: 13, Max.: 41 (for RHD)for LHD - MAX COOL: 33 (pulse)
- MAX HOT: 5 (pulse)
- MAX COOL: 13 (pulse)
- MAX HOT: 41 (pulse)
- Air Outlet Servo Pls (F&R D) Air outlet damper servo motor (for rear seat mode) target pulse /
Min.: 9, Max.: 79FACE1: 9 (pulse)
B/L1: 28 (pulse)
FOOT-O: 41 (pulse)
F/D: 67 (pulse)
DEF: 79 (pulse)- Air Outlet Servo Pulse (R) Rear air outlet damper servo motor target pulse /
Min.: 7, Max.: 83FOOT: 7 (pulse)
B/L: 42 (pulse)
FACE: 83 (pulse)- Room Temperature Sensor (RP) Rear room temperature sensor /
Min.: -6.5°C (20.3°F)
Max.: 57.25°C (135.05°F)Actual rear room temperature displayed Open in the circuit: -6.5°C (20.3°F)
Short in the circuit: 57.25°C (135.05°F)Set Temperature (Rear D side) Rear driver side set temperature /
MAX COLD: 0°C (32°F)
MAX HOT: 32°C (54°F)Rear driver side actual set temperature displayed - Set Temperature (Rear P side) Rear passenger side set temperature /
MAX COLD: 0°C (32°F)
MAX HOT: 32°C (54°F)Rear passenger side actual set temperature displayed - Foot Duct Sensor(Rear D) Min.: -12.7°C (9.14°F)
Max.: 76.55°C (169.79°F)Actual air duct temperature sensor (for driver side) displayed Open in the circuit: -12.7°C (9.14°F)
Short in the circuit: 76.55°C (169.79°F)Foot Duct Sensor(Rear P) Min.: -12.7°C (9.14°F)
Max.: 76.55°C (169.79°F)Actual air duct temperature sensor (for passenger side) displayed Open in the circuit: -12.7°C (9.14°F)
Short in the circuit: 76.55°C (169.79°F)Number of Trouble Codes Number of trouble codes /
Min.: 0, Max.: 255Number of DTCs displayed - A/O Damper FOOT/DEF Pos(P) Air outlet damper servo motor (for DEF mode) target pulse /
Min.: 6, Max.: 117- FACE1: 117 (pulse)
- FACE2: 109 (pulse)
- B/L1: 93 (pulse)
- B/L2: 81 (pulse)
- FOOT-D: 52 (pulse)
- FOOT-R: 41 (pulse)
- FOOT-F: 41 (pulse)
- F/D: 18 (pulse)
- DEF: 6 (pulse)
- Engine Tester Display Measurement Item/Range Normal Condition Diagnostic Note A/C Signal A/C signal / ON or OFF ON: A/C Switch on
OFF: A/C Switch off- - MAX COOL: 9 (pulse)
ACTIVE TEST |
- HINT:
- Using the intelligent tester to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Connect the intelligent tester to the DLC3.
Turn the engine switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Active Test.
According to the display on the intelligent tester, perform the Active Test.
Tester Display Test Part Control Range Diagnostic Note Blower Motor Front blower motor Min.: 0, Max.: 31 - Magnetic Clutch Relay Magnetic clutch relay OFF or ON - Air Mix Servo Targ Pulse(D) Air mix servo motor pulse (Front A/C D side) Min.: 8, Max.: 90 - Air Mix Servo Targ Pulse(P) Air mix servo motor pulse (Front A/C P side) Min.: 8, Max.: 90 - Air Inlet Damper Targ Pulse Air inlet damper target pulse Min.: 9, Max.: 37 - Cool Air Bypass Pulse Driver side cool air bypass pulse Min.: 6, Max.: 57 - Rear Blower Motor Rear blower motor Min.: 0, Max.: 31 - Rear Air Mix Servo Targ Pulse Rear air mix damper servo motor pulse for LHD
Min.: 9, Max.: 54
for RHD
Min.: 8, Max.: 53- DEF A/O Servo Pulse(D) Rear air outlet damper servo motor pulse Min.: 7, Max.: 83 - Rear A/M Servo Pulse(P) Rear air mix damper servo motor (for front passenger side) pulse for LHD
Min.: 8, Max.: 53
for RHD
Min.: 9, Max.: 54- Rear A/C Mag Valve Rear A/C magnetic valve OFF or ON - Face A/O Servo Pulse(D) Air outlet servo motor pulse (D side) Min.: 6, Max.: 117 - Face A/O Servo Pulse(P) Air outlet servo motor pulse (P side) for LHD
Min.: 6, Max.: 117
for RHD
Min.: 9, Max.: 120- A/M Servo Puls(F&R D) Air mix servo motor pulse (Front A/C rear air flow D side) for LHD
Min.: 9, Max.: 54
for RHD
Min.: 8, Max.: 53- A/M Servo Puls(F&R P) Air mix servo motor pulse (Front A/C rear air flow P side) for LHD
Min.: 8, Max.: 53
for RHD
Min.: 9, Max.: 54- A/O Servo Pulse(F&R D) Air outlet servo motor pulse (Front A/C rear air flow D side) Min.: 9, Max.: 79 - A/O Servo Pulse(Rr D) Air outlet servo motor pulse (Rr D side) Min.: 7, Max.: 83 -