CHECK CURTAIN SHIELD AIRBAG LH (CURTAIN SHIELD SQUIB LH 2ND STEP)
CHECK FLOOR WIRE (CURTAIN SHIELD SQUIB LH 2ND STEP CIRCUIT)
DTC B1845/61 Short in Curtain Shield Squib LH 2nd Step Circuit |
DTC B1846/61 Open in Curtain Shield Squib LH 2nd Step Circuit |
DTC B1847/61 Short to GND in Curtain Shield Squib LH 2nd Step Circuit |
DTC B1848/61 Short to B+ in Curtain Shield Squib LH 2nd Step Circuit |
DESCRIPTION
The curtain shield squib LH 2nd step circuit consists of the center airbag sensor and the curtain shield airbag LH.The circuit instructs the SRS to deploy when deployment conditions are met.
These DTCs are stored when a malfunction is detected in the curtain shield squib LH 2nd step circuit.
DTC Code | DTC Detection Condition | Trouble Area |
B1845/61 | When one of the following conditions is met:
|
|
B1846/61 | When one of the following conditions is met:
|
|
B1847/61 | When one of the following conditions is met:
|
|
B1848/61 | When one of the following conditions is met:
|
|
WIRING DIAGRAM

INSPECTION PROCEDURE
- NOTICE:
- After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work (Click here).
- When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Click here).
- HINT:
- To perform the simulation method, enter the check mode (signal check) with the intelligent tester (Click here), and then wiggle each connector of the airbag system or drive the vehicle on various type of road (Click here).
1.CHECK CURTAIN SHIELD AIRBAG LH (CURTAIN SHIELD SQUIB LH 2ND STEP) |
Turn the ignition switch off.
![]() |
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Disconnect the connectors from the curtain shield squib LH 2nd step.
Connect the white wire side of SST (resistance: 2.1 Ω) to connector C.
- CAUTION:
- Never connect the tester to the curtain shield airbag LH (curtain shield squib LH 2nd step) for measurement, as this may lead to a serious injury due to airbag deployment.
- NOTICE:
- Do not forcibly insert SST into the terminals of the connector when connecting SST.
- Insert SST straight into the terminals of the connector.
- SST
- 09843-18061
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Clear the DTCs (Click here).
Turn the ignition switch off.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Check for DTCs (Click here).
- OK:
- DTC B1845, B1846, B1847 or B1848 is not output.
- HINT:
- Codes other than DTC B1845, B1846, B1847 and B1848 may be output at this time, but they are not related to this check.
|
| ||||
OK | ||
|
2.CHECK CONNECTOR |
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Disconnect SST from connector C.
Check that the floor wire connectors (on the curtain shield squib LH 2nd step side) are not damaged.
- OK:
- The lock button is not disengaged, and the claw of the lock is not deformed or damaged.
|
| ||||
OK | |
3.CHECK FLOOR WIRE (CURTAIN SHIELD SQUIB LH 2ND STEP CIRCUIT) |
Disconnect the connectors from the center airbag sensor.
![]() |
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection Switch Condition Specified Condition K9-1 (CL2+) - Body ground Ignition switch ON Below 1 V K9-2 (CL2-) - Body ground Ignition switch ON Below 1 V
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition K9-1 (CL2+) - K9-2 (CL2-) Always Below 1 Ω
Release the activation prevention mechanism built into connector B (Click here).
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition K9-1 (CL2+) - K9-2 (CL2-) Always 1 MΩ or higher K9-1 (CL2+) - Body ground Always 1 MΩ or higher K9-2 (CL2-) - Body ground Always 1 MΩ or higher
|
| ||||
OK | |
4.CHECK CENTER AIRBAG SENSOR |
Connect the connectors to the curtain shield squib LH 2nd step and the center airbag sensor.
![]() |
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Clear the DTCs (Click here).
Turn the ignition switch off.
Turn the ignition switch to ON, and wait for at least 60 seconds.
Check for DTCs (Click here).
- OK:
- DTC B1845, B1846, B1847 or B1848 is not output.
- HINT:
- Codes other than DTC B1845, B1846, B1847 and B1848 may be output at this time, but they are not related to this check.
|
| ||||
OK | ||
|