Meter / Gauge System Meter Illumination Does Not Dim At Night
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
CHECK CAN COMMUNICATION SYSTEM
READ VALUE USING INTELLIGENT TESTER (LIGHT CONTROL RHEOSTAT)
INSPECT LIGHT CONTROL RHEOSTAT
CHECK HARNESS AND CONNECTOR (COMBINATION METER - LIGHT CONTROL RHEOSTAT)
METER / GAUGE SYSTEM - Meter Illumination does not Dim at Night |
DESCRIPTION
w/ Multi-information Display:If the dimmer switch is turned to TAIL, HEAD or AUTO, the main body ECU sends a TAIL relay signal, panel light illumination signal, panel relay signal, and TAIL cancel switch off signal to the combination meter. Then the meter and accessory meter become dim.- HINT:
- TAIL cancel switch: When the headlights are illuminated and the TAIL cancel switch is turned on, the meter does not dim.
WIRING DIAGRAM
INSPECTION PROCEDURE
1.CHECK CAN COMMUNICATION SYSTEM |
Check for DTCs (Click here).
ResultResult
| Proceed to
|
CAN communication system DTC is not output
| A
|
CAN communication system (for LHD) DTC is output
| B
|
CAN communication system (for RHD) DTC is output
| C
|
2.READ VALUE USING INTELLIGENT TESTER (LIGHT CONTROL RHEOSTAT) |
Operate the intelligent tester according to the display and select Data List (Click here).
Combination MeterTester Display
| Measurement Item/Range
| Normal Condition
| Diagnostic Note
|
Tail Cancel SW*
| TAIL cancel switch condition/ON or OFF
| ON: TAIL cancel switch ON OFF: TAIL cancel switch OFF
| -
|
Rheostat value
| Light control rheostat switch input/Min.: 0, Max.: 100
| Light control rheostat switch is fully turned right (0) → fully turned left (100)
| Unit: %
|
- HINT:
- *: w/ TAIL Cancel Switch
- OK:
- Light brightness can be changed within specified range by manual operation.
3.INSPECT LIGHT CONTROL RHEOSTAT |
Inspect the light control rheostat.
Remove the light control rheostat (Click here).
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Switch Condition
| Specified Condition
|
6 (TC) - 1 (E)
| TAIL cancel switch off → on
| 10 kΩ or higher → Below 1 Ω
|
5 (T) - 1 (E)
| Always
| 10 kΩ or higher
|
7 (TR) - 1 (E)
| Light control rheostat fully turned right → fully turned left
| 10 kΩ or higher → Below 100 Ω
|
Inspect the trip switch.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Switch Condition
| Specified Condition
|
4 (A/B) - 1 (E)
| TRIP switch on (Pushed)
| Below 200 Ω
|
TRIP switch off (Not Pushed)
| 1 MΩ or higher
|
4.CHECK HARNESS AND CONNECTOR (COMBINATION METER - LIGHT CONTROL RHEOSTAT) |
Disconnect the E8 meter connector.
Disconnect the E9 rheostat connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
E8-18 (ILL+) - E9-5 (T)
| Always
| Below 1 Ω
|
E8-19 (TR) - E9-7 (TR)
|
E8-23 (E2) - E9-1 (E)
|
E8-20 (TC) - E9-6 (TC)
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|