Dtc B2276 Accr Signal Circuit Malfunction
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
CHECK WHETHER DTC OUTPUT RECURS
CHECK HARNESS AND CONNECTOR (MAIN BODY ECU - ECM)
INSPECT MAIN BODY ECU
DTC B2276 ACCR Signal Circuit Malfunction |
DESCRIPTION
This DTC is stored when a malfunction is detected in the ACCR signal output by the main body ECU.DTC Code
| Detection Condition
| Trouble Area
|
B2276
| The ACCR output circuit inside the main body ECU or other related circuit is malfunctioning.
| - Main body ECU
- ECM
- Harness or connector
|
WIRING DIAGRAM
INSPECTION PROCEDURE
1.CHECK WHETHER DTC OUTPUT RECURS |
Clear the DTCs (Click here).
Check whether DTC B2276 is output 50 seconds or more after the engine switch is turned on (IG).
ResultResult
| Proceed to
|
DTC B2276 output
| A
|
No DTC output
| B
|
| USE SIMULATION METHOD TO CHECK (SYSTEM IS OK) (Click here) |
|
|
2.CHECK HARNESS AND CONNECTOR (MAIN BODY ECU - ECM) |
Disconnect the E2 main body ECU connector.
Disconnect the A38 (for LHD) or A52 (for RHD) ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance (for 1UR-FE, 3UR-FE, 1GR-FE):
Tester Connection
| Condition
| Specified Condition
|
E2-3 (ACCR) - A38-41 (ACCR)*1 E2-3 (ACCR) - A52-41 (ACCR)*2
| Always
| Below 1 Ω
|
E2-3 (ACCR) or A38-41 (ACCR) - Body ground*1 E2-3 (ACCR) or A52-41 (ACCR) - Body ground*2
| Always
| 10 kΩ or higher
|
- HINT:
- *1: for LHD
- *2: for RHD
- Standard Resistance (for 1VD-FTV w/o DPF):
Tester Connection
| Condition
| Specified Condition
|
E2-3 (ACCR) - A38-13 (ACCR)*1 E2-3 (ACCR) - A52-13 (ACCR)*2
| Always
| Below 1 Ω
|
E2-3 (ACCR) or A38-13 (ACCR) - Body ground*1 E2-3 (ACCR) or A52-13 (ACCR) - Body ground*2
| Always
| 10 kΩ or higher
|
- HINT:
- *1: for LHD
- *2: for RHD
- Standard Resistance (for 1VD-FTV w/ DPF):
Tester Connection
| Condition
| Specified Condition
|
E2-3 (ACCR) - A38-22 (ACCR)*1 E2-3 (ACCR) - A52-22 (ACCR)*2
| Always
| Below 1 Ω
|
E2-3 (ACCR) or A38-22 (ACCR) - Body ground*1 E2-3 (ACCR) or A52-22 (ACCR) - Body ground*2
| Always
| 10 kΩ or higher
|
- HINT:
- *1: for LHD
- *2: for RHD
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection
| Condition
| Specified Condition
|
E2-3 (ACCR) - Body ground
| Engine switch pressed and engine cranking
| 11 to 14 V
|
ResultResult
| Proceed to
|
Outside specified range
| A
|
Within specified range (for 1GR-FE)
| B
|
Within specified range (for 1UR-FE)
| C
|
Within specified range (for 3UR-FE)
| D
|
Within specified range (for 1VD-FTV)
| E
|