Vane Pump (For 1Vd-Ftv With Dpf) Inspection
Steering. Land Cruiser. Urj200, 202 Grj200 Vdj200
CHECK OIL CLEARANCE BETWEEN VANE PUMP SHAFT AND VANE PUMP REAR HOUSING BUSHING
INSPECT VANE PUMP ROTOR AND VANE PUMP PLATES
INSPECT FLOW CONTROL VALVE
INSPECT FLOW CONTROL VALVE COMPRESSION SPRING
INSPECT PRESSURE PORT UNION
Vane Pump (For 1Vd-Ftv With Dpf) -- Inspection |
1. CHECK OIL CLEARANCE BETWEEN VANE PUMP SHAFT AND VANE PUMP REAR HOUSING BUSHING |
Using a micrometer, measure the outer diameter [a] of the shaft.
Using a vernier caliper, measure the inner diameter [b] of the rear housing bush.
Calculate the oil clearance.
Oil clearance = Inner diameter of the bush [b] - Outer diameter of the shaft [a]
- Maximum oil clearance:
- 0.08 mm (0.00315 in.)
If the oil clearance is more than the maximum, replace the vane pump assembly.
2. INSPECT VANE PUMP ROTOR AND VANE PUMP PLATES |
Using a micrometer, measure the thickness of the 10 vane pump plates.
Text in Illustration*a
| Thickness
|
- Standard thickness:
- 1.405 to 1.411 mm (0.0553 to 0.0556 in.)
If the thickness is not as specified, replace the vane pump assembly.
Using a feeler gauge, measure the clearance between the side face of the rotor groove and the plate.
Text in Illustration*1
| Protective Tape
|
- Maximum clearance:
- 0.03 mm (0.00118 in.)
If the clearance is more than the maximum, replace the vane pump assembly.
3. INSPECT FLOW CONTROL VALVE |
Coat the flow control valve with power steering fluid and check that it falls smoothly into the valve hole by its own weight.
If the control valve does not fall into the hole smoothly, replace the vane pump assembly.
Check the flow control valve for leakage.
Close one of the holes and apply 390 to 490 kPa (4.0 to 4.9 kgf/cm2, 57 to 71 psi) of compressed air into the opposite side hole, and confirm that air does not come out from the end holes.
If air leaks, replace the vane pump assembly.
4. INSPECT FLOW CONTROL VALVE COMPRESSION SPRING |
Using a vernier caliper, measure the free length of the compression spring.
- Minimum free length:
- 31.3 mm (1.23 in.)
If the length is less than the minimum, replace the vane pump assembly.
5. INSPECT PRESSURE PORT UNION |
Visually check the pressure port union for fluid leaks.