Land Cruiser URJ200 URJ202 GRJ200 VDJ200 - 1UR-FE ENGINE CONTROL
AIR FUEL RATIO SENSOR - INSPECTION
1. INSPECT AIR FUEL RATIO SENSOR |

Measure the resistance according to the value(s) in the table below.
- Standard Resistance (for Bank 1):
Tester Connection Condition Specified Condition 1 (HA1A) - 2 (+B) 20°C (68°F) 1.6 to 3.2 Ω 1 (HA1A) - 4 (A1A-) Always 10 kΩ or higher
- Standard Resistance (for Bank 2):
Tester Connection Condition Specified Condition 1 (HA2A) - 2 (+B) 20°C (68°F) 1.6 to 3.2 Ω 1 (HA2A) - 4 (A2A-) Always 10 kΩ or higher
*A | for Bank 1 |
*B | for Bank 2 |
*a | Component without harness connected (Air Fuel Ratio Sensor) |
If the result is not as specified, replace the air fuel ratio sensor.