Power Window Control System (W/O Jam Protection Function) Power Windows Do Not Operate At All

Vehicle Exterior. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
Window Glass. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25

DESCRIPTION

WIRING DIAGRAM

INSPECTION PROCEDURE

CHECK HARNESS AND CONNECTOR (POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY - BATTERY AND BODY GROUND)

POWER WINDOW CONTROL SYSTEM (w/o Jam Protection Function) - Power Windows do not Operate at All


DESCRIPTION

If all of the power windows do not operate, the power window regulator master switch assembly may have no power or may be malfunctioning.

WIRING DIAGRAM


Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.Window Glass.Power Window Control System (W/ Jam Protection Function).Power Window Control System (W/O Jam Protection Function)  Power Windows Do Not Operate At All


INSPECTION PROCEDURE

NOTICE:
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
1.CHECK HARNESS AND CONNECTOR (POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY - BATTERY AND BODY GROUND)


  1. for Double Cab:



      Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.Window Glass.Power Window Control System (W/ Jam Protection Function).Power Window Control System (W/O Jam Protection Function)  Power Windows Do Not Operate At All
    1. Disconnect the I12 power window regulator master switch assembly connector.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage:
      Tester Connection
      Switch Condition
      Specified Condition
      I12-6 (B) - Body ground
      Ignition switch ON
      11 to 14 V
      Ignition switch off
      Below 1 V
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      I12-3 (E) - Body ground
      Always
      Below 1 Ω


  1. except Double Cab:



      Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.Window Glass.Power Window Control System (W/ Jam Protection Function).Power Window Control System (W/O Jam Protection Function)  Power Windows Do Not Operate At All
    1. Disconnect the I13 power window regulator master switch assembly connector.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage:
      Tester Connection
      Switch Condition
      Specified Condition
      I13-9 (B) - Body ground
      Ignition switch ON
      11 to 14 V
      Ignition switch off
      Below 1 V
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      I13-1 (E) - Body ground
      Always
      Below 1 Ω
Text in Illustration
*a
Front view of wire harness connector
(to Power Window Regulator Master Switch Assembly)


NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY (HILUX_TGN26 RM000002STU06KX.html)