Solar Sensor (For Automatic Air Conditioning System) -- Inspection |
1. INSPECT COOLER THERMISTOR (SOLAR SENSOR) |
![]() |
Connect the connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection Condition Specified Condition 1 (SS+) - 2 (SS-) Sensor not exposed to sunlight or inspection light Below 0.8 V Sensor exposed to sunlight or inspection light 0.8 to 4.3 V
- HINT:
- Check from the rear of the connector while it is connected to the cooler thermistor (solar sensor).
- Use an incandescent light for inspection. Bring it within about 30 cm (11.8 in.) of the cooler thermistor (solar sensor).