Dtc 21 Solar Sensor Circuit

Vehicle Interior. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
Heating Air Conditioning. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25

DESCRIPTION

WIRING DIAGRAM

INSPECTION PROCEDURE

CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY

CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - SOLAR SENSOR)

REPLACE COOLER THERMISTOR (SOLAR SENSOR)

DTC 21 Solar Sensor Circuit


DESCRIPTION

Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.Heating Air Conditioning.Air Conditioning System (For Automatic Air Conditioning System).
Dtc
  21  Solar Sensor Circuit
The cooler thermistor (solar sensor), which is installed on the upper side of the instrument panel, detects sunlight and controls the air conditioning in AUTO mode. The output current from the cooler thermistor (solar sensor) varies according to the amount of sunlight. When the amount of sunlight increases, the output current increases. As the amount of sunlight decreases, the output current decreases. The air conditioning amplifier assembly detects the output current from the cooler thermistor (solar sensor).

DTC Code
Detection Item
Trouble Area
21
An open in cooler thermistor (solar sensor) circuit
(If check is performed in a dark place, DTC 21 may be stored)
  1. Cooler thermistor (solar sensor)
  2. Harness or connector
  3. Air conditioning amplifier assembly

WIRING DIAGRAM


Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.Heating Air Conditioning.Air Conditioning System (For Automatic Air Conditioning System).
Dtc
  21  Solar Sensor Circuit


INSPECTION PROCEDURE

HINT:
If the check is performed in a dark place, DTC 21 may be stored even though the system is normal.
1.CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY


    Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.Heating Air Conditioning.Air Conditioning System (For Automatic Air Conditioning System).
Dtc
  21  Solar Sensor Circuit
  1. Remove the air conditioning amplifier assembly with its connectors still connected (HILUX_TGN26 RM000001K3A01QX.html).

  1. Measure the voltage according to the value(s) in the table below.

    Standard Voltage:
    Tester Connection
    Condition
    Specified Condition
    G95-2 (S5-3) - G95-7 (TS)
    1. Ignition switch ON
    2. Solar sensor subjected to electric light
    3. Vehicle indoors
    0.8 to 4.3 V
    1. Ignition switch ON
    2. Solar sensor covered with a cloth
    3. Vehicle indoors
    Below 0.8 V
    Text in Illustration
    *a
    Component with harness connected
    (Air Conditioning Amplifier Assembly)
    HINT:
    1. As the inspection light is moved away from the sensor, the voltage decreases.
    2. Use an incandescent light for inspection. Bring it within 30 cm (11.8 in.) of the sensor.
    Result
    Result
    Proceed to
    OK (When troubleshooting according to problem symptoms table.)
    A
    OK (When troubleshooting according to DTC.)
    B
    NG
    C


B
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (HILUX_TGN26 RM000001K3A01QX.html)

C
Go to step 2
A

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (HILUX_TGN26 RM0000045E301DX.html)

2.CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER - SOLAR SENSOR)
  1. Disconnect the G95 air conditioning amplifier assembly connector.

  1. Disconnect the G77 cooler thermistor (solar sensor) connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    G95-2 (S5-3) - G77-1 (SS+)
    Always
    Below 1 Ω
    G95-7 (TS) - G77-2 (SS-)
    G95-2 (S5-3) - Body ground
    Always
    10 kΩ or higher
    G95-7 (TS) - Body ground


NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


3.REPLACE COOLER THERMISTOR (SOLAR SENSOR)
  1. Temporally replace the cooler thermistor (solar sensor) with a new or normally functioning one (HILUX_TGN26 RM000001G9N010X.html).

  1. Clear the DTCs (HILUX_TGN26 RM000002LIT02JX.html).

  1. Check the DTCs (HILUX_TGN26 RM000002LIT02JX.html).

    OK:
    DTC code 21 is not output.


NG
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (HILUX_TGN26 RM000001K3A01QX.html)
OK

END (COOLER THERMISTOR [SOLAR SENSOR] IS DEFECTIVE)