  1. INSPECT GENERATOR BRUSH HOLDER ASSEMBLY

  2. INSPECT GENERATOR ROTOR ASSEMBLY

Generator -- Inspection



1. INSPECT GENERATOR BRUSH HOLDER ASSEMBLY


    Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.2Tr-Fe Battery Charging.Charging System.Generator  Inspection
  1. Using a vernier caliper, measure the brush length.

    Standard exposed length:
    10.5 mm (0.413 in.)
    Minimum exposed length:
    4.5 mm (0.177 in.)
    Text in Illustration
    *1
    Length
    If the brush length is less than the minimum, replace the brush holder assembly.


2. INSPECT GENERATOR ROTOR ASSEMBLY


    Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
  1. Check that the bearing is not rough or worn and that it rotates smoothly.
    If necessary, replace the generator rotor assembly.



  1. Check the generator rotor for an open circuit.



      Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.2Tr-Fe Battery Charging.Charging System.Generator  Inspection
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      Slip ring - Slip ring
      20°C (68°F)
      1.85 to 2.25 Ω
      Text in Illustration
      *1
      Slip Ring
      If the result is not as specified, replace the generator rotor assembly.


  1. Check if the generator rotor is grounded.



      Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.2Tr-Fe Battery Charging.Charging System.Generator  Inspection
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      Slip ring - Rotor core
      Always
      10 kΩ or higher
      Text in Illustration
      *1
      Coil Core
      *2
      Slip Ring
      If the result is not as specified, replace the generator rotor assembly.


  1. Check each slip ring.

    1. Check that the slip rings are not rough or scored.
      If rough or scored, replace the rotor assembly.



    2. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25.2Tr-Fe Battery Charging.Charging System.Generator  Inspection
    3. Using a vernier caliper, measure the slip ring diameter.

      Standard diameter:
      14.2 to 14.4 mm (0.559 to 0.567 in.)
      Minimum diameter:
      14.0 mm (0.551 in.)
      Text in Illustration
      *1
      Diameter
      If the diameter is less than the minimum, replace the generator rotor assembly.