Power Source Network. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
2Kd-Ftv Battery Charging. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
Generator (For Denso Made) -- Installation |
1. INSTALL GENERATOR ASSEMBLY |
![]() |
Install the generator with the 2 bolts.
- Torque:
- for bolt A:
- 62 N*m{632 kgf*cm, 46 ft.*lbf}
- for bolt B:
- 25 N*m{255 kgf*cm, 18 ft.*lbf}
Install the generator wire with the nut.
- Torque:
- 9.8 N*m{100 kgf*cm, 87 in.*lbf}
Connect the generator connector.
2. INSTALL NO. 2 IDLER PULLEY ASSEMBLY |
Install the spacer, No. 2 idle pulley and pulley plate with the bolt.
- Torque:
- 45 N*m{459 kgf*cm, 33 ft.*lbf}
3. INSTALL FAN AND GENERATOR V BELT |
Rotate the V-ribbed belt tensioner pulley clockwise, and then install the fan and generator V belt.
- NOTICE:
- Make sure that the fan and generator V belt is set properly on each pulley.
Check that the indicator mark of the V-ribbed belt tensioner (HILUX_TGN26 RM000001475015X.html).
4. INSTALL AIR CLEANER ASSEMBLY |
Connect the air cleaner hose.
Install the cleaner with the 2 bolts.
- Torque:
- 14 N*m{143 kgf*cm, 10 ft.*lbf}
Tighten the hose clamp.
Connect the connector to the mass air flow meter connector.
5. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |
- NOTICE:
- When disconnecting the cable, some systems need to be initialized after the cable is reconnected (HILUX_TGN26 RM000004QR300CX.html).