Engine Hybrid System. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
2Kd-Ftv Emission Control. Hilux. Tgn26, 36 Kun25, 26, 35, 36 Ggn25
Egr Cooler (W/ Dpf) -- Inspection |
1. INSPECT NO. 2 EGR VALVE ASSEMBLY |
When a vacuum of 70 kPa (525 mmHg, 20.67 in.Hg) is applied to the diaphragm chamber, check that the valve turns and air flows out.
![]() |
Maintaining the above conditions, check that there are no leaks and that the valve does not return.
Check that the valve does not have heavy carbon deposits and is not stuck.
If the result is not as specified, replace the No. 2 EGR valve assembly.