Theft Deterrent System (For Hatchback) Security Horn Circuit
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
PERFORM ACTIVE TEST USING TECHSTREAM (SECURITY HORN)
INSPECT SECURITY HORN ASSEMBLY
INSPECT EU-DRL/S-HORN RELAY
CHECK HARNESS AND CONNECTOR (EU-DRL/S-HORN RELAY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY AND SECURITY HORN)
INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
THEFT DETERRENT SYSTEM (for Hatchback) - Security Horn Circuit |
DESCRIPTION
When the theft deterrent system is in the alarm sounding state, the main body ECU outputs a signal repeatedly at 0.4 second intervals, causing the security horn assembly to sound.
WIRING DIAGRAM
INSPECTION PROCEDURE
- NOTICE:
- Inspect the fuses for circuits related to this system before performing the following inspection procedure.
1.PERFORM ACTIVE TEST USING TECHSTREAM (SECURITY HORN) |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Body Electrical / Main Body / Active Test.
according to the display on the Techstream, perform the Active Test.
Main BodyTester Display
| Test Part
| Control Range
| Diagnostic Note
|
Security Horn
| Security horn
| OFF / ON
| -
|
- OK:
- The security horn sounds and stops correctly when operating it through the Techstream.
2.INSPECT SECURITY HORN ASSEMBLY |
Inspect the security horn assembly (YARIS_NCP93 RM0000031YY008X.html).
3.INSPECT EU-DRL/S-HORN RELAY |
Remove the EU-DRL/S-HORN relay from No. 2 engine room relay block.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
3 - 5
| Battery voltage is not applied to terminals 1 and 2
| 10 kΩ or higher
|
Battery voltage is applied to terminals 1 and 2
| Below 1 Ω
|
| REPLACE EU-DRL/S-HORN RELAY |
|
|
4.CHECK HARNESS AND CONNECTOR (EU-DRL/S-HORN RELAY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY AND SECURITY HORN) |
Disconnect the 3C instrument panel junction block assembly connector.
Disconnect the A49 security horn assembly connector.
Measure the resistance and voltage according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
Relay terminal 2 - 3C-20
| Always
| Below 1 Ω
|
Relay terminal 3 - A49-1
| Always
| Below 1 Ω
|
A49-2 - Body ground
| Always
| Below 1 Ω
|
3C-20 - Body ground
| Always
| 10 kΩ or higher
|
A49-1 - Body ground
| Always
| 10 kΩ or higher
|
- Standard Voltage:
Tester Connection
| Condition
| Specified Condition
|
Relay terminal 1 - Body ground
| Always
| 11 to 14 V
|
Relay terminal 5 - Body ground
| Always
| 11 to 14 V
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
5.INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY |
Remove the instrument panel junction block assembly (YARIS_NCP93 RM000003TOE00CX.html).
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
3C-20 - MB-17 (SHRN)
| Always
| Below 1 Ω
|
Text in Illustration*a
| Component without harness connected (Instrument Panel Junction Block Assembly)
|