Dtc B1413 Evaporator Temperature Sensor Circuit
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
READ VALUE USING TECHSTREAM
INSPECT EVAPORATOR TEMPERATURE SENSOR
CHECK HARNESS AND CONNECTOR (A/C AMPLIFIER - EVAPORATOR TEMPERATURE SENSOR)
DTC B1413 Evaporator Temperature Sensor Circuit |
DESCRIPTION
The evaporator temperature sensor (A/C thermistor) is installed on the evaporator in the air conditioning unit. It detects the temperature of the cooled air passed through the evaporator and its signal sent to the A/C amplifier is used to control the air conditioning. The resistance of the evaporator temperature sensor (A/C thermistor) changes in accordance with the temperature of the cooled air passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.The A/C amplifier applies voltage (5 V) to the evaporator temperature sensor (A/C thermistor) and reads voltage changes as the resistance of the evaporator temperature sensor (A/C thermistor) changes. This sensor is used to prevent the evaporator from freezing.DTC No.
| DTC Detection Condition
| Trouble Area
|
B1413
| Open or short in evaporator temperature sensor circuit
| - Evaporator temperature sensor
- Harness or connector between evaporator temperature sensor and A/C amplifier
- A/C amplifier
|
WIRING DIAGRAM
INSPECTION PROCEDURE
1.READ VALUE USING TECHSTREAM |
Connect the Techstream to the DLC3.
Turn the ignition switch to ON.
Turn the Techstream on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
Air ConditionerTester Display
| Measurement Item/Range
| Normal Condition
| Diagnostic Note
|
Evaporator Fin Thermistor (Evap Fin Temp)
| Evaporator fin temperature / Min.: -29.7°C (-21.46°F), Max.: 59.55°C (139.19°F)
| Actual evaporator temperature displayed
| Open in circuit: -29.7°C (-21.46°F) Short in circuit: 59.55°C (139.19°F)
|
- OK:
- The display is as specified in the "Normal Condition" column.
- Result:
Result
| Proceed to
|
NG
| A
|
OK (When troubleshooting according to Problem Symptoms Table)
| B
|
OK (When troubleshooting according to the DTC output)
| C
|
2.INSPECT EVAPORATOR TEMPERATURE SENSOR |
Remove the evaporator temperature sensor.
Disconnect the connector from the evaporator temperature sensor.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
E67-1 - E67-2
| -10°C (14°F)
| 7.30 to 9.10 kΩ
|
E67-1 - E67-2
| -5°C (23°F)
| 5.65 to 6.95 kΩ
|
E67-1 - E67-2
| 0°C (32°F)
| 4.40 to 5.35 kΩ
|
E67-1 - E67-2
| 5°C (41°F)
| 3.40 to 4.15 kΩ
|
E67-1 - E67-2
| 10°C (50°F)
| 2.70 to 3.25 kΩ
|
E67-1 - E67-2
| 15°C (59°F)
| 2.14 to 2.58 kΩ
|
E67-1 - E67-2
| 20°C (68°F)
| 1.71 to 2.05 kΩ
|
E67-1 - E67-2
| 25°C (77°F)
| 1.38 to 1.64 kΩ
|
E67-1 - E67-2
| 30°C (86°F)
| 1.11 to 1.32 kΩ
|
- NOTICE:
- Hold the sensor only by its connector. Touching the sensor may change the resistance value.
- When measuring, the sensor temperature must be the same as the ambient temperature.
- HINT:
- As the temperature increases, the resistance decreases (see the graph).
Text in Illustration*a
| Component without harness connected (Evaporator Temperature Sensor)
|
*b
| Sensing Portion
|
*c
| Resistance (kΩ)
|
*d
| Allowable Range
|
*e
| Temperature (°C (°F))
|
3.CHECK HARNESS AND CONNECTOR (A/C AMPLIFIER - EVAPORATOR TEMPERATURE SENSOR) |
Disconnect the connector from the A/C amplifier.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
E62-10 (TE) - E67-1*1
| Always
| Below 1 Ω
|
E62-11 (SG-3) - E67-2*1
| Always
| Below 1 Ω
|
E62-10 (TE) - Body ground*1
| Always
| 10 kΩ or higher
|
E62-11 (SG-3) - Body ground*1
| Always
| 10 kΩ or higher
|
E111-22 (TE) - E67-1*2
| Always
| Below 1 Ω
|
E111-23 (SG-3) - E67-2*2
| Always
| Below 1 Ω
|
E111-22 (TE) - Body ground*2
| Always
| 10 kΩ or higher
|
E111-23 (SG-3) - Body ground*2
| Always
| 10 kΩ or higher
|
- *1: except TMC Made 2AZ-FE
- *2: for TMC Made and except TMC Made 2ZR-FE
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|