INSPECT SHIFT LOCK CONTROL UNIT ASSEMBLY (w/o Smart Key System)
INSPECT SHIFT LOCK CONTROL UNIT ASSEMBLY (w/ Smart Key System)
Shift Lever -- Inspection |
1. INSPECT SHIFT LOCK CONTROL UNIT ASSEMBLY (w/o Smart Key System) |
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection Condition Specified Condition 6 (ACC) - 1 (E) Ignition switch ON 11 to 14 V 6 (ACC) - 1 (E) Ignition switch ACC 11 to 14 V 6 (ACC) - 1 (E) Ignition switch off Below 1 V 4 (STP) - 1 (E) Brake pedal depressed 11 to 14 V 4 (STP) - 1 (E) Brake pedal released Below 1 V 5 (KLS+) - 1 (E) Ignition switch ACC and shift lever P Below 1 V Ignition switch ACC and shift lever except P (Within approx. 1 second) 7.5 to 11 V Ignition switch ACC and shift lever except P (After approx. 1 second) 6 to 9.5 V 8 (IG) - 1 (E) Ignition switch ON 11 to 14 V 8 (IG) - 1 (E) Ignition switch off Below 1 V
- NOTICE:
- Do not disconnect the shift lock control unit assembly connector.
![]() |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition 1 (E) - Body ground Always Below 1 Ω
- NOTICE:
- Do not disconnect the shift lock control unit assembly connector.
![]() |
2. INSPECT SHIFT LOCK CONTROL UNIT ASSEMBLY (w/ Smart Key System) |
Measure the voltage according to the value(s) in the table below.
- Standard Voltage:
Tester Connection Condition Specified Condition 8 (IG) - 1 (E) Engine switch on (IG) 11 to 14 V 8 (IG) - 1 (E) Engine switch off Below 1 V 4 (STP) - 1 (E) Brake pedal depressed 11 to 14 V 4 (STP) - 1 (E) Brake pedal released Below 1 V
- NOTICE:
- Do not disconnect the shift lock control unit assembly connector.
![]() |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition 1 (E) - Body ground Always Below 1 Ω
- NOTICE:
- Do not disconnect the shift lock control unit assembly connector.
![]() |
3. INSPECT TRANSMISSION CONTROL SWITCH |
Disconnect the transmission control switch connector of the shift lock control unit assembly.
Measure the resistance according to the value(s) in the table below when the shift lever is moved to each position.
- Standard Resistance:
Tester Connection Shift Position Specified Condition 1 (NSSD) - 2 (AT3) 3 and 2 Below 1 Ω 1 (NSSD) - 2 (AT3) Except 3 and 2 10 kΩ or higher
![]() |
4. INSPECT SHIFT LOCK SOLENOID |
Disconnect the shift lock solenoid connector.
Measure the resistance according to the value(s) in the table below when the shift lever is moved to each position.
- Standard Resistance:
Tester Connection Shift Position Specified Condition 1 (P) - 2 (E2) P 10 kΩ or higher 1 (P) - 2 (E2) Except P Below 1 Ω
![]() |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection Condition Specified Condition 3 (SLS-) - 4 (SLS+) Always 112 Ω