Air Conditioning System Back-Up Power Source Circuit
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
INSPECT FUSE (A/C)
INSPECT AIR CONDITIONING AMPLIFIER (AIR CONDITIONING AMPLIFIER - BODY GROUND)
AIR CONDITIONING SYSTEM - Back-up Power Source Circuit |
DESCRIPTION
The back-up power source circuit for the A/C amplifier is shown below. Power is supplied even when turning the ignition switch to the LOCK position and is used for diagnostic trouble code memory, etc.
WIRING DIAGRAM
INSPECTION PROCEDURE
Remove the A/C fuse from the instrument panel J/B.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Item
| Condition
| Specified Condition
|
A/C fuse
| Always
| Below 1 Ω
|
2.INSPECT AIR CONDITIONING AMPLIFIER (AIR CONDITIONING AMPLIFIER - BODY GROUND) |
Disconnect the A/C amplifier connector.
Measure the voltage according to the value(s) in the table below.
- Standard voltage:
Tester Connection
| Condition
| Specified Condition
|
E38-21 (B) - Body ground
| Always
| 10 to 14 V
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
OK |
|
|
|
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE |
|