Air Conditioning System (For Automatic Air Conditioning System) Data List / Active Test

Heater & Air Conditioning System. Toyota Rav4. Aca30, 33, 38 Gsa33 Zsa30, 35
Air Conditioning. Toyota Rav4. Aca30, 33, 38 Gsa33 Zsa30, 35
  1. READ DATA LIST

  1. PERFORM ACTIVE TEST

Air Conditioning System (For Automatic Air Conditioning System) -- Data List / Active Test



READ DATA LIST
Toyota Rav4. Aca30, 33, 38 Gsa33 Zsa30, 35.Air Conditioning.Air Conditioning System (For Automatic Air Conditioning System).Air Conditioning System (For Automatic Air Conditioning System)  Data List / Active Test
HINT:
Using the intelligent tester's Data List allows switch, sensor, actuator and other item values to be read without removing any parts. Reading the Data List early in troubleshooting is one way to save time.
  1. Connect the intelligent tester to the DLC3.

  2. Turn the ignition switch on (IG) and turn the intelligent tester ON.

  3. Read the Data List by following the prompts on the tester.

    Air conditioning amplifier
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Room Temperature Sensor
    Room temperature sensor /
    Min.: -6.5°C (20.3°F)
    Max.: 57.25°C (135.05°F)
    Actual room temperature is displayed
    Open circuit: -6.5°C (20.3°F)
    Short circuit: 57.25°C (135.05°F)
    Ambient Temp Sensor
    Ambient temperature sensor /
    Min.: -23.3°C (-9.94°F)
    Max.: 65.95°C (150.71°F)
    Actual ambient temperature is displayed
    Open circuit: -23.3°C (-9.94°F)
    Short circuit: 65.95°C (150.71°F)
    Adjusted Ambient Temp
    Adjusted ambient temperature /
    Min.: -30.8°C (-23.44°F)
    Max.: 50.8°C (123.44°F)
    -
    -
    Evaporator Fin Thermistor
    Evaporator temperature sensor /
    Min.: -29.7°C (-21.46°F)
    Max.: 59.55°C (139.19°F)
    Actual evaporator temperature is displayed
    Open circuit: -29.7°C (-21.46°F)
    Short circuit: 59.55°C (139.19°F)
    Solar Sensor (D side)
    Driver side solar sensor /
    Min.: 0, Max.: 255
    Driver side solar sensor value increases as brightness increases
    -
    Solar Sensor (P side)
    Passenger side solar sensor /
    Min.: 0, Max.: 255
    Passenger side solar sensor value increases as brightness increases
    -
    Engine Coolant Temp
    Engine coolant temperature /
    Min.: 1.3°C (34.34°F)
    Max.: 90.55°C (194.99°F)
    Actual engine coolant temperature is displayed after engine warmed up
    -
    Set Temperature (D side)
    Driver side set temperature /
    Min.: 0°C (32°F)
    Max.: 30°C (54°F)
    Driver side actual set temperature is displayed
    -
    Set Temperature (P side)
    Passenger side set temperature /
    Min.: 0°C (32°F)
    Max.: 30°C (54°F)
    Passenger side actual set temperature is displayed
    -
    Blower Motor Speed Level
    Blower motor speed level /
    Min.: 0 level, Max.: 31 level
    Increases 0 to 31 as blower motor speed increases
    -
    Regulator Pressure Sensor
    Regulator pressure sensor /
    Min.: -0.45668 MPaG
    Max.: 3.29437 MPaG
    Actual regulator pressure is displayed
    -
    Regulator Control Current
    Regulator control current /
    Min.: 0 A
    Max.: 0.997 A
    Value changes between 0 A and 0.997 A in accordance with compressor operation
    -
    Air Mix Servo Targ Pulse (D)
    Driver side air mix servo motor target pulse /
    Min.: 0, Max.: 255
    LHD:
    MAX. COLD: 92 (pulse)
    MAX. HOT: 5 (pulse)
    RHD:
    MAX. COLD: 6 (pulse)
    MAX. HOT: 93 (pulse)
    -
    Air Mix Servo Targ Pulse (P)
    Passenger side air mix servo motor target pulse /
    Min.: 0, Max.: 255
    LHD:
    MAX. COLD: 6 (pulse)
    MAX. HOT: 93 (pulse)
    RHD:
    MAX. COLD: 92 (pulse)
    MAX. HOT: 5 (pulse)
    -
    Air Outlet Servo Pulse (D)
    Air outlet servo motor target /
    Min.: 0, Max.: 255
    FACE: 47 (pulse)
    B/L: 37 (pulse)
    FOOT: 17 (pulse)
    FOOT/DEF: 9 (pulse)
    DEF: 5 (pulse)
    -
    Air Inlet Damper Targ Pulse
    Air inlet damper target pulse /
    Min.: 0, Max.: 255
    LHD:
    RECIRCULATION: 19 (pulse)
    FRESH: 7 (pulse)
    RHD:
    RECIRCULATION: 7 (pulse)
    FRESH: 25 (pulse)
    -
    Electric Heater Count
    Electric (PTC) heater count /
    Min.: 0
    Max.: 3
    Actual number of the heater elements to be heated is displayed
    -
    Shift Set Temperature
    Shift set temperature / +2 C, +1 C, NORMAL, -1 C, -2 C
    Customized value displayed
    -
    Air Inlet Mode
    Air inlet mode /
    AUTO, MANUAL
    Customized value displayed
    -
    Compressor Mode
    Compressor mode /
    AUTO, MANUAL
    Customized value displayed
    -
    Compressor/DEF Mode
    Compressor / DEF Mode /
    LINK, NORMAL
    Customized value displayed
    -
    Evaporator Control
    Evaporator Control /
    AUTO, MANUAL
    Customized value displayed
    -
    Foot/DEF Auto Mode
    Foot / DEF auto mode /
    ON, OFF
    Customized value displayed
    -
    Foot/DEF Auto Blow Up
    Foot / DEF automatic blow up function /
    ON, OFF
    Customized value displayed
    -
    Ambient Temperature Shift
    Ambient temperature shift / +3C, +2C, +1C, Normal, -1C, -2C, -3C
    Customized value displayed
    -
    Number of Trouble Codes
    Number of trouble codes /
    Min.: 0, Max.: 255
    Number of DTCs displayed
    -

PERFORM ACTIVE TEST
HINT:
Performing the intelligent tester's Active Test allows relays, the VSV, actuators and other items to be operated without removing any parts. Performing the Active Test early in troubleshooting is one way to save time. The Data List can be displayed in the Active Test.
  1. Connect the intelligent tester to the DLC3.

  2. Turn the ignition switch on (IG) and turn the intelligent tester ON.

  3. Perform the Active Test by following the prompts on the tester.

    Air conditioning amplifier
    Tester Display
    Test Part
    Control Range
    Diagnostic Note
    Blower Motor
    Blower motor
    Min.: 0, Max.: 31
    -
    Magnetic Clutch Relay
    Magnetic clutch relay
    OFF, ON
    -
    Defogger Relay (Rear)
    Defogger relay (Rear)
    OFF, ON
    -
    Electric Heater 1
    PTC heater No. 1 relay
    OFF, ON
    -
    Electric Heater 2
    PTC heater No. 2 relay
    OFF, ON
    -
    Air Mix Servo Targ Pulse (D)
    Air mix servo motor pulse
    Min.: 0, Max.: 255
    -
    Air Mix Servo Targ Pulse (P)
    Air mix servo motor pulse (P side)
    Min.: 0, Max.: 255
    -
    Air Outlet Servo Pulse (D)
    Air outlet servo motor pulse
    Min.: 0, Max.: 255
    -
    Air Inlet Damper Targ Pulse
    Air inlet damper target pulse
    Min.: 0, Max.: 255
    -