Ignition Relay No. 2 On-Vehicle Inspection
Engine. Toyota Rav4. Aca30, 33, 38 Gsa33 Zsa30, 35
DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
REMOVE IG2 RELAY
INSPECT IG2 RELAY
INSTALL IG2 RELAY
CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Ignition Relay No. 2 -- On-Vehicle Inspection |
1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL |
- CAUTION:
- Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt pretensioner activation.
Remove the No. 1 engine room relay block cover.
Remove the IG2 relay from the engine room relay block.
Measure the resistance of the IG2 relay.
- Standard resistance:
Tester Connection
| Specified Condition
|
3 - 5
| 10 kΩ or higher
|
3 - 5
| Below 1 Ω (when battery voltage is applied to terminals 1 and 2)
|
If the result is not as specified, replace the relay.
5. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |