Power Window Regulator Motor (For Front Door) -- Inspection |
1. INSPECT FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH |
Apply positive (+) battery voltage to the connector terminal 2 (B).
- NOTICE:
- Do not apply positive (+) battery voltage to any terminals except terminal 2 (B) to avoid damaging the pulse sensor inside the motor.
![]() |
Apply negative (-) battery voltage to the connector terminals 1 (GND) and 7 (DOWN) or 10 (UP).
Check that the motor gear rotates smoothly as follows.
- OK:
Measurement Condition Specified Condition - Connect the positive (+) battery cable to terminal 2 (B), and connect the negative (-) battery cable to terminal 1 (GND), and keep them connected for 3 seconds or more.
- With terminals 2 (B) and 1 (GND) connected, connect the negative (-) battery cable to terminal 10 (UP).
- Disconnect and reconnect the negative (-) battery cable to terminal 10 (UP) within 1 second.
Motor gear rotates clockwise (Up) - Connect the positive (+) battery cable to terminal 2 (B), and connect the negative (-) battery cable to terminal 1 (GND), and keep them connected for 3 seconds or more.
- With terminals 2 (B) and 1 (GND) connected, connect the negative (-) battery cable to terminal 7 (DOWN).
- Disconnect and reconnect the negative (-) battery cable to terminal 7 (DOWN) within 1 second.
Motor gear rotates counterclockwise (Down) - Connect the positive (+) battery cable to terminal 2 (B), and connect the negative (-) battery cable to terminal 1 (GND), and keep them connected for 3 seconds or more.
- If the result is not as specified, replace the front power window regulator motor assembly LH.
- CAUTION:
- Reset the power window regulator motor (initialize the pulse sensor) after installing the power window regulator motor and regulator assembly onto the door.
Text in Illustration *1 Motor Gear *a Clockwise *b Counterclockwise
2. INSPECT FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH |
Apply positive (+) battery voltage to the connector terminal 2 (B).
- NOTICE:
- Do not apply positive (+) battery voltage to any terminals except terminal 2 (B) to avoid damaging the pulse sensor inside the motor.
![]() |
Apply negative (-) battery voltage to the connector terminals 1 (GND) and 7 (DOWN) or 10 (UP).
Check that the motor gear rotates smoothly as follows.
- OK:
Measurement Condition Specified Condition - Connect the positive (+) battery cable to terminal 2 (B), and connect the negative (-) battery cable to terminal 1 (GND), and keep them connected for 3 seconds or more.
- With terminals 2 (B) and 1 (GND) connected, connect the negative (-) battery cable to terminal 10 (UP).
- Disconnect and reconnect the negative (-) battery cable to terminal 10 (UP) within 1 second.
Motor gear rotates counterclockwise (Up) - Connect the positive (+) battery cable to terminal 2 (B), and connect the negative (-) battery cable to terminal 1 (GND), and keep them connected for 3 seconds or more.
- With terminals 2 (B) and 1 (GND) connected, connect the negative (-) battery cable to terminal 7 (DOWN).
- Disconnect and reconnect the negative (-) battery cable to terminal 7 (DOWN) within 1 second.
Motor gear rotates clockwise (Down) - Connect the positive (+) battery cable to terminal 2 (B), and connect the negative (-) battery cable to terminal 1 (GND), and keep them connected for 3 seconds or more.
- If the result is not as specified, replace the front power window regulator motor assembly RH.
- CAUTION:
- Reset the power window regulator motor (initialize the pulse sensor) after installing the power window regulator motor and regulator assembly onto the door.
Text in Illustration *1 Motor Gear *a Clockwise *b Counterclockwise