CHECK LIN COMMUNICATION SYSTEM
CHECK MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY (WINDOW LOCK SWITCH)
POWER WINDOW CONTROL SYSTEM - Remote Up / Down Function does not Operate |
DESCRIPTION
When the ignition switch is ON and the window lock switch is off, the multiplex network master switch sends remote up/down signals to each power window regulator motor via the LIN communication line.INSPECTION PROCEDURE
1.CHECK LIN COMMUNICATION SYSTEM |
Check for LIN communication system DTCs related to the power window control system (LandCruiser RM000001RSO0BWX.html).
- OK:
- LIN communication system DTCs are not output.
|
| ||||
OK | |
2.CHECK MULTIPLEX NETWORK MASTER SWITCH ASSEMBLY (WINDOW LOCK SWITCH) |
Turn the window lock switch off and operate the switches on the multiplex network master switch. Check that the remote up/down function operates (LandCruiser RM000002STU0ARX.html).
- OK:
- Remote up/down function operates.
![]() |
|
| ||||
OK | ||
|