Rear Evaporator Temperature Sensor Inspection
INSPECT REAR EVAPORATOR TEMPERATURE SENSOR
Rear Evaporator Temperature Sensor -- Inspection |
1. INSPECT REAR EVAPORATOR TEMPERATURE SENSOR |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
7 (-) - 8 (+)
| -10°C (14°F)
| 7.30 to 9.10 kΩ
|
-5°C (23°F)
| 5.65 to 6.95 kΩ
|
0°C (32°F)
| 4.40 to 5.35 kΩ
|
5°C (41°F)
| 3.40 to 4.15 kΩ
|
10°C (50°F)
| 2.70 to 3.25 kΩ
|
15°C (59°F)
| 2.14 to 2.58 kΩ
|
20°C (68°F)
| 1.71 to 2.05 kΩ
|
25°C (77°F)
| 1.38 to 1.64 kΩ
|
30°C (86°F)
| 1.11 to 1.32 kΩ
|
If the result is not as specified, replace the rear evaporator temperature sensor.
- NOTICE:
- Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
- When measuring, the sensor temperature must be the same as the ambient temperature.
- HINT:
- As the temperature increases, the resistance decreases (see the graph).
Text in Illustration*a
| Component without harness connected (Rear Evaporator Temperature Sensor)
|
*b
| Sensing Portion
|
*c
| Resistance (kΩ)
|
*d
| Allowable Range
|
*e
| Temperature °C (°F)
|