Generator -- Installation |
1. INSTALL GENERATOR ASSEMBLY |
Install the generator assembly with the 3 bolts.
- Torque:
- 43 N*m{438 kgf*cm, 32 ft.*lbf}
Connect the wire harness to terminal B with the nut.
- Torque:
- 9.8 N*m{100 kgf*cm, 87 in.*lbf}
Install the terminal cap.
Connect the connector to the generator assembly.
2. INSTALL FAN AND GENERATOR V BELT |
Install the fan and generator V belt to all the pulleys except the tensioner pulley.
Text in Illustration *1 Generator Assembly *2 Idler Pulley Sub-assembly *3 Vane Pump Assembly *4 Fan Pulley *5 Tensioner Pulley *6 Crankshaft Pulley *7 No. 1 Idler Pulley Sub-assembly *8 Cooler Compressor Assembly
![]() |
Use the hexagonal part indicated by the arrow in the illustration to move the tensioner pulley downward and install the fan and generator V belt to the tensioner pulley.
- NOTICE:
- The backside of the fan and generator V belt should face the tensioner pulley.
- Check that the fan and generator V belt is properly set on each pulley.
3. INSTALL AIR CLEANER CAP SUB-ASSEMBLY WITH AIR CLEANER HOSE |
Install the air cleaner cap sub-assembly with air cleaner hose and align its matchmark with the matchmark of the intake air connector as shown in the illustration.
Text in Illustration *a Upper *b Front *c Matchmark
![]() |
Tighten the hose clamp.
- NOTICE:
- Check that the air cleaner hose is securely installed.
Attach the 4 clamps.
Attach the 3 clamps and connect the intake mass air flow meter connector.
4. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL |
- NOTICE:
- When disconnecting the cable, some systems need to be initialized after the cable is reconnected (LandCruiser RM000003YMF011X.html).