Generator -- Disassembly |
1. INSPECT GENERATOR WITH VACUUM PUMP ASSEMBLY |
Mount the generator in a vise between aluminum plates.
Insert a screwdriver to hold the generator rotor.
![]() |
Install a bolt and nut to the outside of the pulley so that the bolt head and nut clamp the pulley, and then position a dial indicator as shown in the illustration.
Turn the pulley and measure the backlash between the generator rotor and vacuum pump shaft.
- Maximum backlash:
- 1.6 mm (0.0630 in.)
2. REMOVE VACUUM PUMP ASSEMBLY |
Place matchmarks as shown in the illustration.
Text in Illustration *a Matchmark
![]() |
Remove the 4 bolts and vacuum pump.
3. REMOVE GENERATOR REAR END COVER |
Remove the nut and terminal insulator.
![]() |
Remove the bolt, 3 nuts, rectifier plate and rear end cover.
4. REMOVE GENERATOR BRUSH HOLDER ASSEMBLY |
Remove the brush holder cover.
Remove the 2 screws and brush holder.
![]() |
Remove the plate seal.
5. REMOVE GENERATOR REGULATOR ASSEMBLY |
Remove the 3 screws and generator regulator.
![]() |
6. REMOVE GENERATOR HOLDER WITH RECTIFIER |
Remove the 4 screws and generator holder with rectifier.
![]() |
Remove the 4 rubber insulators.
7. REMOVE GENERATOR RECTIFIER END FRAME |
Remove the 4 nuts and cord clip.
Text in Illustration *1 Cord Clip
![]() |
Using SST, remove the rectifier end frame.
- SST
- 09286-46011
Text in Illustration *a Hold Turn
![]() |
Remove the washer from the rotor.
8. REMOVE GENERATOR ROTOR ASSEMBLY |
Using SST and a press, press out the rotor.
- SST
- 09950-60010(09951-00180)
09950-70010(09951-07100)
![]() |