Vacuum Pump (For 5L-E) -- On-Vehicle Inspection |
1. OPERATION CHECK |
Disconnect the vacuum hose from the vacuum pump.
Connect the hose of a vacuum gauge to the pump.
Text in Illustration *1 Vacuum Gauge *2 Plug
![]() |
Insert a plug into the other hose of the gauge.
Start the engine and warm it up for more than 2 minutes.
With the engine idling, measure the negative pressure of the pump.
- Standard negative pressure:
- More than 86.7 kPa (650 mmHg, 26 in.Hg)
Remove the gauge from the pump.
Connect the hose to the pump with the clip.