Control Valve Assembly Inspection
INSPECT NO. 2 HEIGHT CONTROL VALVE SUB-ASSEMBLY
Control Valve Assembly -- Inspection |
1. INSPECT NO. 2 HEIGHT CONTROL VALVE SUB-ASSEMBLY |
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
1 (LH+) - 2 (E)
| 15 to 25°C (59 to 77°F)
| 10 to 14 Ω
|
3 (RH+) - 2 (E)
|
Text in Illustration*a
| Component without harness connected (No. 2 Height Control Valve)
|
Check the operating sound of the height control valve when battery voltage is applied to the terminals.
- OK:
Measurement Condition
| Specified Condition
|
1 (LH+) - 2 (E)
| Sound of No. 2 height control valve operating can be heard
|
3 (RH+) - 2 (E)
|
If the result is not as specified, replace the No. 2 height control valve sub-assembly.