Terminal No. (Symbol)
| Wiring Color
| Terminal Description
| Condition
| Specified Condition
|
G53-9 (RLY1) - G54-4 (GND)
| G - W-B
| Rear differential lock actuator limit switch
| Ignition switch ON Rear differential lock actuator limit switch on
| Below 1.5 V
|
Ignition switch ON Rear differential lock actuator limit switch off
| 11 to 14 V
|
G53-10 (RLY2) - G54-4 (GND)
| P - W-B
| Rear differential lock actuator limit switch
| Ignition switch ON Rear differential lock actuator limit switch on
| Below 1.5 V
|
Ignition switch ON Rear differential lock actuator limit switch off
| 11 to 14 V
|
G53-3 (R) - G54-4 (GND)
| R - W-B
| w/ Combination Switch: Center cluster module switch (Rear differential lock control switch)
| Ignition switch ON Rear differential lock switch on
| Below 1.5 V
|
Ignition switch ON Rear differential lock switch off
| 11 to 14 V
|
w/o Combination Switch: Differential lock switch
| Ignition switch ON Rear differential lock switch on
| Below 1.5 V
|
Ignition switch ON Rear differential lock switch off
| 11 to 14 V
|
G53-15 (RLP) - G54-4 (GND)
| V - W-B
| Rear differential lock detection switch
| Ignition switch ON Rear differential lock detection switch on
| Below 1.5 V
|
Ignition switch ON Rear differential lock detection switch off
| 9.5 to 14 V
|
G54-1 (M1) - G54-4 (GND)
| B - W-B
| Differential lock actuator motor
| Ignition switch ON Differential lock switch off → on (Differential lock switch OFF → ON (For 5 seconds after power supplied or until switching of limit switch is complete during FREE to LOCK switching))
| 11 to 14 V
|
Ignition switch ON Differential lock switch off → on (Differential lock actuator motor stopped)
| Below 1.5 V
|
G54-3 (IG) - G54-4 (GND)
| R - W-B
| IG power
| Ignition switch ON
| 11 to 14 V
|
G54-4 (GND) - Body ground
| W-B - Body ground
| Ground
| Always
| Below 1 Ω
|
G54-5 (M2) - G54-4 (GND)
| Y - W-B
| Differential lock actuator motor
| Ignition switch ON Differential lock switch on → off (Differential lock switch ON → OFF (For 5 seconds after power supplied or until switching of limit switch is complete during LOCK to FREE switching))
| 11 to 14 V
|
Ignition switch ON Differential lock switch on → off (Differential lock actuator motor stopped)
| Below 1.5 V
|
G53-19 (CANH) - G54-4 (GND)
| G - W-B
| CAN communication line
| Ignition switch ON
| Pulse generation (see waveform 1)
|
G53-20 (CANL) - G54-4 (GND)
| W - W-B
| CAN communication line
| Ignition switch ON
| Pulse generation (see waveform 2)
|