Automatic Transmission System (For 1Gr-Fe) Pattern Select Switch 2Nd Start Mode Circuit
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
INSPECT PATTERN SELECT (2ND) SWITCH ASSEMBLY
CHECK HARNESS AND CONNECTOR (PATTERN SELECT (2ND) SWITCH - BODY GROUND)
CHECK HARNESS AND CONNECTOR (PATTERN SELECT (2ND) SWITCH - ECM)
AUTOMATIC TRANSMISSION SYSTEM (for 1GR-FE) - Pattern Select Switch 2nd Start Mode Circuit |
DESCRIPTION
When 2nd start mode is selected with the pattern select (2ND) switch, the ECM controls the solenoid valves and the transmission starts from 2nd gear.In 2nd start mode, the system operates the throttle motor to control engine output to reduce skidding of the drive wheels and guarantee stable acceleration from rest, straight driving and turning stability.When the shift lever is in D, the transmission automatically shifts up from 2nd to 6th as usual.- HINT:
- The pattern select (2ND) switch is a momentary-type switch.
- In order to cancel 2nd start mode, push the pattern select (2ND) switch again or turn the engine switch off.
WIRING DIAGRAM
INSPECTION PROCEDURE
1.INSPECT PATTERN SELECT (2ND) SWITCH ASSEMBLY |
Remove the pattern select (2ND) switch assembly (LandCruiser RM0000046J800OX_02_0019.html).
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Switch Condition
| Specified Condition
|
1 (E) - 4 (2ND)
| Pattern select (2ND) switch pushed
| Below 1 Ω
|
1 (E) - 4 (2ND)
| Pattern select (2ND) switch not pushed
| 10 kΩ or higher
|
Text in Illustration*1
| Pattern Select (2ND) Switch Assembly
|
2.CHECK HARNESS AND CONNECTOR (PATTERN SELECT (2ND) SWITCH - BODY GROUND) |
Disconnect the pattern select (2ND) switch connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
G159-1 (E) - Body ground
| Always
| Below 1 Ω
|
Text in Illustration*a
| Front view of wire harness connector (to Pattern Select (2ND) Switch Assembly)
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
3.CHECK HARNESS AND CONNECTOR (PATTERN SELECT (2ND) SWITCH - ECM) |
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Switch Condition
| Specified Condition
|
G55-19 (SNWI) - Body ground
| Pattern select (2ND) switch pushed
| Below 1 Ω
|
G55-19 (SNWI) - Body ground
| Pattern select (2ND) switch not pushed
| 10 kΩ or higher
|
Text in Illustration*a
| Rear view of wire harness connector (to ECM)
|