Urea Pump Inspection


  1. INSPECT UREA PUMP

Urea Pump -- Inspection



1. INSPECT UREA PUMP


  1. Inspect the level sensor.



      Land Cruiser, Land Cruiser Prado. Grj150 Trj150,155 Kdj150,155 Lj150, Gdj150,155.1Gd-Ftv Emission Control.Emission Control System.Urea Pump  Inspection
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      14(LV1) - 6(ELV1)
      Float position is upper
      23.37 to 24.47 kΩ
      Float position is lower
      1.40 to 1.46 kΩ
      Text in Illustration
      *a
      Component without harness connected
      (Urea Pump)
      *b
      Upper
      *c
      Lower


  1. Inspect the tank heater.



      Land Cruiser, Land Cruiser Prado. Grj150 Trj150,155 Kdj150,155 Lj150, Gdj150,155.1Gd-Ftv Emission Control.Emission Control System.Urea Pump  Inspection
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      9(TH+) - 11(TH-)
      25°C (77°F)
      1.39 to 1.54 kΩ
      Text in Illustration
      *a
      Component without harness connected
      (Urea Pump)


  1. Inspect the temperature sensor.



      Land Cruiser, Land Cruiser Prado. Grj150 Trj150,155 Kdj150,155 Lj150, Gdj150,155.1Gd-Ftv Emission Control.Emission Control System.Urea Pump  Inspection
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      1(TUW) - 2(ETUW)
      20°C (68°F)
      2.47 to 2.56 kΩ
      30°C (86°F)
      1.69 to 1.75 kΩ
      Text in Illustration
      *a
      Component without harness connected
      (Urea Pump)


  1. Inspect the pump motor.



      Land Cruiser, Land Cruiser Prado. Grj150 Trj150,155 Kdj150,155 Lj150, Gdj150,155.1Gd-Ftv Emission Control.Emission Control System.Urea Pump  Inspection
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      7(PHAA) - 8(PHAB)
      20 to 30 °C (68 to 86°F)
      0.35 to 0.43 Ω
      7(PHAA) - 16(PHAC)
      8(PHAB) - 16(PHAC)
      7(PHAA) - 15(MGND)
      Always
      10 kΩ or higher
      8(PHAB) - 15(MGND)
      16(PHAC) - 15(MGND)
      Text in Illustration
      *a
      Component without harness connected
      (Urea Pump)
      If the result is not as specified, replace the urea pump.