Front Seat Inner Belt Assembly (For Power Seat) Inspection
INSPECT FRONT SEAT INNER BELT ASSEMBLY (for Driver Side)
INSPECT FRONT SEAT INNER BELT ASSEMBLY (for Front Passenger Side)
INSPECT OCCUPANT DETECTION SENSOR
INSPECT PASSENGER SEAT BELT WARNING LIGHT ASSEMBLY (w/o Accessory Meter)
Front Seat Inner Belt Assembly (For Power Seat) -- Inspection |
1. INSPECT FRONT SEAT INNER BELT ASSEMBLY (for Driver Side) |
Measure the resistance of the buckle switch.
- Standard resistance:
Tester Connection
| Condition
| Specified Condition
|
1 - 2
| Seat belt unfastened
| Below 1 Ω
|
1 - 2
| Seat belt fastened
| 1 MΩ or higher
|
If the result is not as specified, replace the belt assembly.
2. INSPECT FRONT SEAT INNER BELT ASSEMBLY (for Front Passenger Side) |
Measure the resistance of the buckle switch.
- HINT:
- Before performing the buckle switch check, perform the previous step (inspect occupant detection sensor) to make sure the occupant detection sensor is functioning normally.
- Standard resistance:
Tester Connection
| Condition
| Specified Condition
|
1 - 2
| Seat belt is unfastened and more than 147 N (15 kgf, 33 lbf) of force is applied to occupant detection sensor
| Below 100 Ω
|
1 - 2
| No force applied to occupant detection sensor
| 1 MΩ or higher
|
If the result is not as specified, replace the inner belt assembly.
3. INSPECT OCCUPANT DETECTION SENSOR |
Measure the resistance of the sensor.
- Standard resistance:
Tester Connection
| Condition
| Specified Condition
|
1 - 2
| More than 147 N (15 kgf, 33 lbf) applied to occupant detection sensor
| Below 100 Ω
|
1 - 2
| No force applied to occupant detection sensor
| 1 MΩ or higher
|
If the result is not as specified, replace the occupant detection sensor (separate type front seat cushion pad).
4. INSPECT PASSENGER SEAT BELT WARNING LIGHT ASSEMBLY (w/o Accessory Meter) |
Check the illumination area of the seat belt warning light.
- OK:
Measurement Condition
| Specified Condition
|
Battery positive (+) → 3 (IG) Battery negative (-) → 2 (SW), 1 (GND)
| Illuminates
|
If the result is not as specified, replace the accessory meter.