Dtc P2716/77 Pressure Control Solenoid D Electrical (Shift Solenoid Valve Slt)
DESCRIPTION
WIRING DIAGRAM
INSPECTION PROCEDURE
INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT)
CHECK WIRE HARNESS (SHIFT SOLENOID VALVE SLT - TCM)
INSPECT SHIFT SOLENOID VALVE SLT
DTC P2716/77 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT) |
DESCRIPTION
The throttle pressure that is applied to the primary regulator valve (which modulates the line pressure) causes solenoid valve SLT, under electronic control, to precisely modulate and generate the line pressure according to the extent that the accelerator pedal is depressed or the output of engine power.This controls the line pressure and provides smooth shifting characteristics.Upon receiving a signal of the throttle valve opening angle, the TCM controls the line pressure by sending a predetermined current to the solenoid valve, modulating the line pressure and generating throttle pressure.DTC Code
| DTC Detection Condition
| Trouble Area
|
P2716/77
| TCM detects shift solenoid valve SLT circuit malfunction for 1 sec. or more (1 trip detection logic)
| - Open or short in shift solenoid valve SLT circuit
- Shift solenoid valve SLT
- TCM
|
WIRING DIAGRAM
INSPECTION PROCEDURE
1.INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT) |
Disconnect the E1 wire connector.
Measure the resistance of the transmission wire.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
2 (SLT+) - 6 (SLT-)
| 20°C (68°F)
| 5.0 to 5.6 Ω
|
2 (SLT+) - Body ground
| Always
| 10 kΩ or higher
|
6 (SLT-) - Body ground
| Always
| 10 kΩ or higher
|
2.CHECK WIRE HARNESS (SHIFT SOLENOID VALVE SLT - TCM) |
Disconnect the T19 TCM connector.
Measure the resistance of the wire harness side connector.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
T19-20 (SLT+) - T19-19 (SLT-)
| 20°C (68°F)
| 5.0 to 5.6 Ω
|
T19-20 (SLT+) - Body ground
| Always
| 10 kΩ or higher
|
T19-19 (SLT-) - Body ground
| Always
| 10 kΩ or higher
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
3.INSPECT SHIFT SOLENOID VALVE SLT |
Remove the shift solenoid valve SLT.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
| Condition
| Specified Condition
|
1 - 2
| 20°C (68°F)
| 5.0 to 5.6 Ω
|
Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.
- OK:
Measurement Condition
| Specified Condition
|
- Battery positive (+) with a 21 W bulb → Terminal 2
- Battery negative (-) → Terminal 1
| Valve moves and makes an operating noise
|
| REPLACE SHIFT SOLENOID VALVE SLT |
|
|
OK |
|
|
|
REPLACE TRANSMISSION WIRE |
|