Thermostat -- Inspection |
1. INSPECT THERMOSTAT |
![]() |
- HINT:
- The valve opening temperature is inscribed on the thermostat.
Immerse the thermostat in water and then gradually heat the water.
![]() |
Check the valve opening temperature.
- Standard valve opening temperature:
- 80 to 84°C (176 to 183°F)
- If the valve opening temperature is not within the specified range, replace the thermostat.
Check the valve lift.
- Standard valve lift:
- 10 mm (0.39 in.) or more at 95°C (203°F)
- If the valve lift is not as specified, replace the thermostat.
![]() |
Check that the valve is fully closed when the thermostat is below 40°C (104°F).
- If not fully closed, replace the thermostat.
- If not fully closed, replace the thermostat.