Heated Oxygen Sensor (For Unleaded Gasoline Specification Vehicle) -- Inspection |
1. INSPECT HEATED OXYGEN SENSOR (for Bank 1 Sensor 1) |
Measure the resistance between terminals 1 (HT1A) and 2 (+B) of the sensor.
- Standard resistance:
- 5 to 10 Ω at 20°C (68°F)
![]() |